Page 1
Attach copy of data label here! CANTERBURY FREESTANDING MODELS Date installed: ......................Compliance Certificate No ..................For service to this appliance or spare parts contact the CANNON distributor: Sampford IXL Cannon Phone: 1300 727 421 This heater is approved for use with Fax: 1300 727 425 email: aftersalesservice@sampfordixl.com.au...
Contents Notes Contents Warranty Distributor Safety warnings What to do if you smell gas Warnings Standards User instructions Operating instructions Flame characteristics Cleaning Heater specifications Installation instructions 10-15 Clearances Installation Gas connection Log installation Gas control Flue installation Installation tips 16-17 Gas control Gas pressure point...
Trade Practices Act and similar laws of the States and Territories. We warrant this Cannon appliance to be free of defects in materials, workmanship and manufacturing to the original purchaser for 2 years, (10 years on the heat exchanger) from the date of original purchase.
Page 4
Refer to other sections of this FIG 1. manual for correct procedures, or consult with place of purchase, a licensed plumber, a gas supplier or the CANNON distributor listed in this manual. Listen for cracking sound. The spark is Spark is being produced misdirected.
Before testing the flue confirm that any air vents are unobstructed. If an spark connection, gas supply exhaust fan, rangehood or other heating appliances are present switch them on. This will test that there is no interaction between the CANNON heater and Check Flame sense electrode, Flame failure lockout any other appliances when they are operating at the same time.
Service instructions (Do not modify this appliance) User instructions To replace the room circulation fan 1. Remove the lower pedestal front by unscrewing four off screws 2 either Operating instructions side. 2. Disconnect the fan plug from the plug carrier. Remove the two M5 1.
User instructions Service instructions (Do not modify this appliance) General Flame characteristics 1. Service work to be carried out by an authorised service person only. The heater flame should be stable, no lifting off from the burner base and the 2.
Gas control Heater specifications 4. Switch the heater to Hi Flame to as indicated in Fig 4(a) and using a Note: Gas type: Natural or Propane gas, as indicated ring spanner and screwdriver, as per Fig 4(b), hold screwdriver in The data plate is on data plate.
Gas control Heater specifications 1. Gas control layout is as indicated in Fig 1. Pressures for ‘Burner full on’ and ‘Burner low flame’ are Important: factory set, however if pressures need to be checked or EARTH SWITCH ON/OFF adjusted follow the procedures described below and on the To achieve the correct next two pages.
Installation instructions Flue installation Overall dimensions: Refer to Heater Specifications on Page 8. 1. This appliance is to be installed by a suitably licensed person only. 2. This appliance shall be installed in accordance with these manufacturer’s installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, and AS5601 the Australian Stand- ard for gas installations.
Flue installation Installation instructions This heater is a flued appliance. It must be properly connected to a flue system in accordance with the latest edition of the Gas Installation Code, AS 5601. If elbows are required, we recommend 45 ? only and no more than two in the total flue run, there should also be a minimum of 250mm straight flue section in between bends..
Installation instructions Installation instructions Position the four individually numbered logs in the following order on the burner head as shown in figures 6 - 9. The male locating pins in If the flame is unstable: the burner head must engage with corresponding holes in the individual logs.