Gas Control; Gas Pressure Point - Cannon FITZPIB User Instructions

Inbuilt models fitzroy profile
Table of Contents

Advertisement

Gas control

Gas pressure point

23. Gas control layout is as indicated in figure 33.
Pressures for 'Burner full on' and 'Burner low flame' are fac-
tory set, however if pressures need to be checked or adjusted
follow the procedures described below and on the next two
pages.
33
To check control outlet pressure at burner 'Full on" and 'Low Flame"
positions remove the plastic cap from the regulator adjustment lo-
cation as indicated in figures 34 (a) & (b).
34
24 The pressure point is closed with a captive screw. Turn screw 6
revolution anticlockwise to open the pressure point as indicated on
figure 35 (a) and place manometer tube over the test point as per
figure 35 (b).
35
17