Gas Pressure Point - Cannon CANT User Instructions

Freestander models
Table of Contents

Advertisement

Gas pressure point

d) Place log No. 4 on single right back pin, ensure left side
of log rests on depression in No. 3 log, see figure 20.
20
14. Refit the inner glass, but do not overtighten the screws.
15. Refit the front glass surround. Ensure that the glass surround is
replaced the correct side up. The rearward sloping frame must
be at the top and the vertical ledge must be at the bottom.
Refer figure 21.
21
16. Using an 8mm spanner remove the pressure point cover and
check the outlet pressure of the gas regulator. It should be 1.0
kPa for NG, 2.75 for LP gas. Adjustment for LP gas is at the
gas bottle regulator. The outlet pressure point is situated on the
RHS top of the gas control. Refer figure 22
22
17. Refit the pedestal cover.
18. Follow User Instructions to turn on heater.
Important:
To achieve the correct visual flame effect:
On Propane the gas pressure must be set at 2.75 kPa
with burner operating on maximum setting.
On Natural Gas the gas pressure must be set at 1.0 kPa.
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

CantlpCanterbury cantCanterbury cantlp

Table of Contents