Cannon Canterbury CANTIB-SDEEB Instruction Manual

Cannon Canterbury CANTIB-SDEEB Instruction Manual

Inbuilt heater

Advertisement

Canterbury
CANTIB-SDEEB
Distributor
This appliance is designed, manufactured and distributed by:
Tel: 1300 727 421
Sharing a lifetime of cosy moments
Inbuilt Heater
Instruction Manual
Please read this manual before
installing and using this heater.
FITZIB-SMENB, FITZIB-SMEXB, FITZIB-SMEXP
Please leave instruction manual with the owner
Fitzroy

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Canterbury CANTIB-SDEEB and is the answer not in the manual?

Questions and answers

Summary of Contents for Cannon Canterbury CANTIB-SDEEB

  • Page 1 Sharing a lifetime of cosy moments Inbuilt Heater Instruction Manual Please read this manual before installing and using this heater. Canterbury Fitzroy CANTIB-SDEEB FITZIB-SMENB, FITZIB-SMEXB, FITZIB-SMEXP Please leave instruction manual with the owner Distributor This appliance is designed, manufactured and distributed by: Tel: 1300 727 421...
  • Page 2: Table Of Contents

    CANTErBury INBuIlT FASCIA rEMOvAl ElECTrICAl CONNECTION & SEAlINg THE FASCIA INSTAllINg THE FluE SPIgOT lOg INSTAllATION & gAS CONNECTION SETTINg THE gAS PrESSurE SErvICE INSTruCTIONS 17 –18 WIrINg DIAgrAM TrOuBlESHOOTINg 20 – 21 2 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 3: Warranty

    This Warranty against defects for your newly purchased c. will not apply where the defect in or failure of Cannon product is proudly prepared by Sampford IXl Pty the product is attributable to misuse, abuse, ltd of 421 Smith Street, Fitzroy, vIC 3065, accident or non-observation of the manufacturer’s...
  • Page 4 11. Sampford IXl and its Authorised Service Dealers reserve the right to seek reimbursement of any costs incurred by them should your Cannon product be found to be in good working order. Privacy The privacy of your personal information has always been important to us.
  • Page 5: Safety Warnings

    (CO) licensed plumber, a gas supplier or the CANNON poisoning and possible death. distributor listed in this manual.
  • Page 6: Operation

    High wind gusts can affect the heaters flueing and switch the heater off. If this happens, restart the ON / OFF heater as normal. If the problem persists contact Sampford IXL. NORMAL BOOST fig 1 fig 2 6 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 7: Optional Accessories

    (normal heat setting only). Speak to your home add a decorative 3 or 4 sided surround. automation specialist for further information. Every Cannon heater brings you the optional convenience of being controlled via a remote thermostat. flue kit Product codes •...
  • Page 8: Inbuilt: Fitzroy Specifications

    • The data label is located in the fan chamber. Access by removing front fascia. 385 mm 50 mm 229 mm 41 mm 808 mm fig 3 front View and side View 8 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 9: Inbuilt: Canterbury Specifications

    • The data label is located in the fan chamber. Access by removing front fascia. 338 mm 125 mm 180 mm 41 mm 850 mm fig 4 front View and side View Cannon Fitzroy / Canterbury Inbuilt | 9...
  • Page 10: Fitzroy & Canterbury Inbuilt Installation Instructions

    This is to test and ensure Make sure that the heater is fully commissioned and that there is no interaction between the Cannon heater be certain to conduct a test of the integrity of the flue and other appliances.
  • Page 11: Fitzroy & Canterbury Inbuilt Installation Instructions

    100 mm Rear wall of fireplace 900 mm min clearance 25 mm min 700 - 790 mm 690 mm 690 mm 100 mm ** 50 mm ** Ensure controls are visible fig 6 Cantib-sDeeb Cannon Fitzroy / Canterbury Inbuilt | 11...
  • Page 12: Fitzroy & Canterbury Inbuilt Fluing Options

    Ø100mm flue The flue must be fixed in place. Heater Install heater Transition rectangular to 100mm round. onto a solid, (supplied as standard) leveled base. fig 7 this diagram is a general guide only. 12 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 13: Fitzroy Inbuilt Fascia Removal

    3. To remove the front heater surround undo two screws (one either side) from the bottom flange of the front panel as indicated in FIG 13. fig 10 fig 11 fig 12 grommet Grommet fig 13 fig 14 fig 15 Cannon Fitzroy / Canterbury Inbuilt | 13...
  • Page 14: Electrical Connection & Sealing The Fascia

    3 steP 4 fiXing of the fasCia you MuST NOT fix the front fascia to the wall. The front fascia shall only be fixed to the heater. 14 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 15: Log Installation & Gas Connection

    Sealing is 69 mm 69 mm important as it prevents any leakage of flue products into the room. Test all connections for gas leaks. fitzroy fig 23 Canterbury fig 24 Cannon Fitzroy / Canterbury Inbuilt | 15...
  • Page 16: Setting The Gas Pressure

    • Check that flue is operating correctly If the heater still does not operate to specification refer to the troubleshooting chart on pages 20 & 21, or contact Sampford IXl in your state. adjust fig 29 16 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 17: Service Instructions

    Move the bracket and controls to the front of the heater. 3. Disconnect the fan plug from the plug carrier. remove the two M5 wing nuts which locate the fan to the fan Electronic controller Ignition module gas valve fig 30 Cannon Fitzroy / Canterbury Inbuilt | 17...
  • Page 18 Flame sense electrode must be in constant flame. Check for gas tightness. For log placement refer page 15 of this manual. To Replace Power Cord Contact Sampford IXl service department. fig 32 fig 33 fig 33 Securing the burner bed 18 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 19: Wiring Diagram

    IGNITION MODULE PRESSURE F3833 SWITCH F3327 240 V MAINS PLUG ROOM AIR FAN NATURALLY ASPIRATED WIRING DIAGRAM F3835 B fig 34 BEEP fig 35 switch Control Diagram highlighting ng/lP settings & audible beep. Cannon Fitzroy / Canterbury Inbuilt | 19...
  • Page 20: Troubleshooting

    One wire should be to C (Common) and the other should be to NO (Normally Open). If it still doesn’t work after checking the above, change the pressure switch. 20 | Cannon Fitzroy / Canterbury Inbuilt...
  • Page 21: Troubleshooting

    • Check that there is gas to the inlet of the gas control. Fuse blowing. • If the fuse continues to blow check the solenoid coils for a signs of them being shorted. • Check the fan and wiring for short circuit. Cannon Fitzroy / Canterbury Inbuilt | 21...
  • Page 22 22 | Cannon Canterbury Freestanding...
  • Page 23 Cannon Canterbury Freestanding | 23...
  • Page 24 For service to this appliance or spare parts Gmk 10025 contact the CANNON distributor: Gmk 10030 AS4553:2008 Sampford IXL – Spare Parts Phone: 1300 727 421 Part number: Fax: 1300 727 425 Email: aftersalesservice@sampfordixl.com.au F3841_B 24 | Cannon Fitzroy / Canterbury Inbuilt...