Battery Replacement; Figure 25: Two Power Inlets - Electric Caution Notifications - Mellanox Technologies SwitchX-2 User Manual

60 port ethernet switch system
Hide thumbs Also See for SwitchX-2:
Table of Contents

Advertisement

SwitchX®-2 60 Port Ethernet Switch System Hardware User Manual
tacle. The input voltage is auto-adjusting for 100 - 240VAC, 50-60Hz power connections. The
power cords should be standard 3-wire AC power cords including a safety ground and rated for
15A or higher.
Risk of electric shock and energy
hazard. The two PS units are
independent.
Disconnect all power supplies to
ensure a powered down state
inside of the switch platform.
4.7

Battery Replacement

Mellanox Technologies does not support battery replacement. Customer removal of the switch
cover will void the warrantee. Only Remove the cover to comply with WEEE directives or to dis-
assemble for environmentally approved disposal.
Caution: The switch platform will automatically power on when AC power is applied.
There is no power switch. Check all boards, power supplies, and fan tray modules for
proper insertion before plugging in a power cable.
This unit is intended for installation in a Restricted Access Location. A restricted
access area can be accessed only through the use of a special tool, lock and key, or
other means of security.
Caution: After inserting a power cable and confirming the green system status LED
light is on; make sure that the Fan Status indicator shows green.
If the fan status indicator is not green then unplug the power connection and check that
the fan module is inserted properly and that the mating connector of the fan unit is free
of any dirt and/or obstacles.
Caution: When turning off the switch, make sure ALL Connector LEDS are off to
ensure a powered down status.
Do not hot swap the power supply if your switch has only one power supply. You must
power down the system to replace the power supply unit when there is only one PS
unit in the switch.

Figure 25: Two Power Inlets - Electric Caution Notifications

CAUTION
Gafahr des elektrischen
Schocks. Entferrnen des
Netzsteckers elnes Netz-
teils spannungsfrei. Um
alle Einhieten spannungs-
frei zu machen sind die
Netzstecker aller Netzteile
zu entfernen
ACHTUNG
Risque de choc et de danger 
e'lectriques. Le de'branch-
ment d'une seule alimentation
stabilise'e ne de'branch
uniquement qu'un module
"Alimentation Stabilise'e".
Pour isoler completement le
module en cause, Il faut
de'brancher toutes les alimen-
tations stabilise'es.
ATTENTION
Mellanox Technologies
Rev 1.1
35