SwitchX®-2 60 Port Ethernet Switch System Hardware User Manual
If the switch comes on, Use the MLNX-OS® management CLI to determine the
5.
cause of the Shutdown.
Check the temperature.
6.
Check the Fan status.
7.
The switch is not working and unresponsive:
Issue 8.
Reset the switch.
1.
If resetting the switch does not work:
Unplug the switch.
1.
Wait 5 minutes.
2.
Plug in the switch.
3.
If the switch does not come on, check the power supplies.
4.
If the switch comes on, use the MLNX-OS® management CLI to determine the
5.
cause of the shutdown.
The last software update did not succeed:
Issue 9.
Connect the RS232 connector (CONSOLE) to a laptop.
1.
Push the reset button on the switch or management module.
2.
You will have ~ 5 seconds to stop the U-Boot by pressing Control-B.
3.
Choose the image to upload. Only use image 1 or image 2.
4.
U-Boot 2009.01-mlnx1.4 (<date>)
CPU:
Board: Mellanox PPC460EX Board
FDEF: No
I2C:
DRAM:
FLASH: 16 MB
NAND: 1024 MiB
PCI:
PCIE0: link is not up.
PCIE1: successfully set as root-complex
Net:
Hit Ctrl+B to stop autoboot: 0
Mellanox MLNX-OS
Boot Menu:
AMCC PowerPC 460EX Rev. A at 1000 MHz (PLB=200, OPB=100, EBC=100 MHz)
Security/Kasumi support
Bootstrap Option H - Boot ROM Location I2C (Addr 0x52)
Internal PCI arbiter disabled
32 kB I-Cache 32 kB D-Cache
ready
2 GB (ECC enabled, 400 MHz, CL3)
Bus Dev VenId DevId Class Int
01 00 15b3 bd34 0c06 00
ppc_4xx_eth0, ppc_4xx_eth1
1. SX_PPC_M460EX 3.2.0000-dev-HA 2013-04-10 12:02:49 ppc