  • Page 1 SwitchX® 64 Port SFP+ Ethernet Switch Hardware User Manual P/N: MSX1016X-2BFR, MSX1016X-2BRR Rev 1.2 www.mellanox.com...
  • Page 2 SwitchX®, Virtual Protocol Interconnect® and Voltaire® are registered trademarks of Mellanox Technologies, Ltd. Connect-IB™, FabricIT™, MLNX-OS™, ScalableHPC™, Unbreakable-Link™, UFM™ and Unified Fabric Manager™ are trademarks of Mellanox Technologies, Ltd. All other trademarks are property of their respective owners. Document Number: 3727...
  • Page 3: Table Of Contents

    5.2.2 Upgrading Software ......... 30 Mellanox Technologies...
  • Page 4 Appendix G Installation - Sicherheitshinweise (German) ....47 Appendix H Advertencias de seguridad para la instalación (Spanish)..51 Appendix I Special Regulations Regarding Finland, Sweden, Denmark, and Norway 54 Mellanox Technologies...
  • Page 5: List Of Figures

    Figure 20: Transfer Power Cord Finished ........39 Mellanox Technologies...
  • Page 6 Table 10: Replacement Parts Ordering Numbers ....... 43 Mellanox Technologies...
  • Page 7: Revision History

    Revision Description November 2012 Rev 1.2 Removed Updating FW section; not needed for Ethernet switches October 2012 Rev 1.1 • Added China CCC Warning Statement • Fixes to port to LED assignment February 2012 Rev 1.0 Initial release Mellanox Technologies...
  • Page 8: About This Manual

    This symbol indicates information that is helpful to the user. This symbol indicates a situation that can potentially cause damage to hardware or software. BEWARE! This symbol indicates a situation that can potentially cause personal injury or damage to hardware or software. Mellanox Technologies...
  • Page 9: Mellanox Part Numbering Legend

    SwitchX® 64 Port SFP+ Ethernet Switch Hardware User Manual Rev 1.2 Mellanox Part Numbering Legend Place Field Decoder Mellanox Technologies System Type SwitchX® silicon Protocol (1, 2, 3, 4) = Ethernet Height of Unit 0 = 1U 1 = 1.5U...
  • Page 10: Chapter 1 Overview

    • Reset Push button on front panel • Front Panel indication LEDs: • Status LED (Red / Yellow / Green) • Fans Status LED (Red / Green) • UID LED (Blue) • Bad port LED (Yellow / Green) Mellanox Technologies...
  • Page 11: Serial Number And Product Version Information

    Near this label is another label with the management MAC. Figure 2: Generic Product label S/N: MT0924X00266 P/N: MSX1016X‐2BFR Rev: X1 MAC: 0002C902004C Made in Israel Figure 3: Management MAC Label Management MAC:  0002C902004C Mellanox Technologies...
  • Page 12: Chapter 2 Installation Safety Warnings

    During periods of lightning activity, do not work on the equipment or connect or dis- connect cables. 6. Copper Cable Connecting/Disconnecting Copper cables are heavy and not flexible, as such they should be carefully attached to or detached from the connectors. Refer to the cable manufacturer for special warnings/ instructions. Mellanox Technologies...
  • Page 13 This device must be installed according to the latest version of the country national electrical codes. For North America, equipment must be installed in accordance to the applicable requirements in the US National Electrical Code and the Canadian Electrical Code. Mellanox Technologies...
  • Page 14 According to the WEEE Directive 2002/96/EC, all waste electrical and electronic equipment (EEE) should be collected separately and not disposed of with regular household waste. Dispose of this product and all of its parts in a responsible and environmentally friendly way. Mellanox Technologies...
  • Page 15: Chapter 3 Hardware Basic Operation And Installation

    When the switch is plugged in, within four minutes the following LEDs should be evident. • The Status LED should light up green. • The Fan LED should light up green. • The Bad Port LED should be off. • The Unit ID LED should be off. Figure 5: Status LEDs Mellanox Technologies...
  • Page 16: Table 3: Switch Status Led Configurations

    Table 4 - Fan LED Configurations LED Configuration FAN LED There is no power to the fans. Green OK – the fans are running. Error – the fans are not operating properly. Replace the switch. Mellanox Technologies...
  • Page 17: Table 5: Bad Port Led Configurations

    3.1.1.5 UID LED Switch Identifier The UID LED is a debug feature that will become available to customers in the near future. For details please contact Mellanox Technologies support. 3.1.1.6 Port Connector LED The port LEDs are assigned to the ports as in figure:...
  • Page 18: Port Connector Led Assignment

    The air flow is specified in the product model number. See “Mellanox Part Numbering Legend” on page 9. SFP+ Cable Power Budget Classification This switch is designed for active cables with a max power per module of 1.0W. Mellanox Technologies...
  • Page 19: Interfaces

    First Time”. For the Socket pinout see “RJ45 CONSOLE and Ethernet Interfaces” on page 51. 3.5.2 Mini USB This interface can be used to update SW. 3.5.3 RJ-45 Ethernet Connector The Ethernet connection labelled provides access for remote management. The switch can be connected to any Ethernet port. Mellanox Technologies...
  • Page 20: I2C Connector

    It can take up to 4 minutes to boot up, during which time the status LED may indicate red. 3.5.4 I2C Connector There is an “I2C”interface on the side panel. This interface is only for FAEs and advanced users. Mellanox Technologies...
  • Page 21: Chapter 4 Installation

    Table 7 - Installation Kit According to Rack Size Kit OPN Rack Size MSX60-BKIT 40-60 cm MSX60-SKIT 60-80 cm For racks from 60cm to 80cm deep either use the standard depth switches with the long rail kit or the short switches with the long rail kit. Mellanox Technologies...
  • Page 22: Figure 9: Rack Rail Kit Parts

    2. Choose which side of the switch you want even with the rack vertical support. Either the side with the power supply units or the side with the SFP+ connectors can be even with one of the vertical rack supports. Things to consider before choosing where to mount the rails and rail slides. Mellanox Technologies...
  • Page 23: Figure 10: Placement Of Switch In Rack

    5cm by optional placement of the switch rails. See Figure 11,“Mounting Options”. • Will the connector side be recessed past other equipment in the rack and will this be problematic? • The installation kit allows for a 2” recess of the switch past the vertical support. Mellanox Technologies...
  • Page 24 Transferring the Power Cord - Section Appendix C:. 4. Screw the switch slides onto the switch. Use 5 flat head screws for short switches and 7 screws for standard depth switches, to connect each switch slide. Mellanox Technologies...
  • Page 25: Figure 12: Screwing On The Rail

    7. Slide the rail into the rail slide. 8. Using two of the bolts for each corner install the rails and rail slides in the rack. Do not tighten the bolts yet. Mellanox Technologies...
  • Page 26: Power Connections And Initial Power On

    Each PSU has a separate AC receptacle. The input voltage is auto-adjusting for 90 - 264 VAC, 50-60Hz power connections. The power cords should be standard 3-wire AC power cords includ- ing a safety ground and rated for 15A or higher. Mellanox Technologies...
  • Page 27: Grounding The Switch

    (that is, when the unit is powered on and a cable is plugged into the port with the other end of the connector plugged into a functioning port). After plugging in a cable, lock the connector using the latching Mellanox Technologies...
  • Page 28: Cable Orientation

    (EEE) should be collected separately and not disposed of with regular household waste. Dispose of this product and all of its parts in a responsible and environmentally friendly way. For proper disassembly instructions see the Mellanox website. Mellanox Technologies...
  • Page 29: Chapter 5 Management And Tools Overview

    DB9 connector of the local host PC. Figure 16: Host Connection Manage- SX1016 Mellanox CONSOLE 5.2.1 Starting a Remote Connection to the Switch For details on the SNMP commands and MIBs supported refer the MLNX-OS Soft- ware Command Reference Guide. Mellanox Technologies...
  • Page 30: Upgrading Software

    Use the CLI or the GUI in order to perform Software upgrade. For further information please refer to the MLNX-OS user manual. Be sure to read and follow all of the instructions regarding the updating of the software on your switch system. Mellanox Technologies...
  • Page 31: Chapter 6 Troubleshooting

    5. If the switch comes on, use the management software to determine the cause of the shutdown. 6. Check the temperature of the switch. 7. Check the ambient air temperature to make sure it is not too high. 8. Check the Fan status. Mellanox Technologies...
  • Page 32 3. Plug in the switch. 4. If the switch does not come on, check the power supplies. 5. If the switch comes on, use the management software to determine the cause of the shutdown. 6. Reset the switch. Mellanox Technologies...
  • Page 33: Appendix A Specification

    Temperature: Cable power / MAX 1.0W Operating 0° to 45° Celsius Temperature TYP: 0.8W Non-operating -40° to 70° Celsius Shock and  Humidity: Shock and Vibration: ETSI EN 300 019-2-2: 1999-09 Operating 5% - 95% non-condensing Vibration/ Humidity Mellanox Technologies...
  • Page 34: Approved Cables

    For a list of all approved cables see: www.mellanox.com/related-docs/user_manuals/Mellanox_approved_cables.pdf EMC Certifications The list of approved certifications per switch in different regions of the world is located on the Mellanox website at: www.mellanox.com/related-docs/user_manuals/Regulatory_and_Compliance_Guide.pdf EMC statements are also in the Regulatory and Compliance Guide. Mellanox Technologies...
  • Page 35: China Ccc Warning Statement

    SwitchX® 64 Port SFP+ Ethernet Switch Hardware User Manual Rev 1.2 China CCC Warning Statement Mellanox Technologies...
  • Page 36: Appendix B Thermal Threshold Definitions

    When the SwitchX® device crosses this temperature, the firmware will automatically shut down the device. 3. Emergency – 130C In case the firmware fails to shut down the SwitchX® device upon crossing the Critical thresh- old, the SwitchX® device will auto-shutdown upon crossing the Emergency (130C) threshold. Mellanox Technologies...
  • Page 37: Appendix C Transferring The Power Cord

    4. Push the cord end through the hole in the switch slide. Leave ~ 7” of cord hanging out from the hole. Figure 18: Put the Cord Through the Switch Slide Before Screwing it to the Switch 5. Screw the switch slides to the switch. Mellanox Technologies...
  • Page 38: Figure 19: Screw The Switch Slide To The Switch

    Rev 1.2 Figure 19: Screw the Switch Slide to the Switch Figure 20: Transfer Power Cord Finished 6. Return to step 4 on page 24 and continue the installation. Mellanox Technologies...
  • Page 39: Appendix D Sfp+ Interface

    SwitchX® 64 Port SFP+ Ethernet Switch Hardware User Manual Rev 1.2 Appendix D: SFP+ Interface 13.90 11.85 1.55 0.50 8.50 0.60 2.55 1.80 44.95 56.50 Mellanox Technologies 13.60 14.80 13.70 MTSFPP-SR Module Mellanox Technologies...
  • Page 40: Table 9: Sfp+ Pinout

    Loss of Signal indication. Logic 0 indicates normal operation. No connection required VeeR Receiver Ground (Common with Transmitter Ground) VeeR Receiver Ground (Common with Transmitter Ground) Receiver Inverted DATA out. AC Coupled Receiver Non-inverted DATA out. AC Coupled VeeR Receiver Ground (Common with Transmitter Ground) Mellanox Technologies...
  • Page 41 MOD_ABS pulls line low to indicate module is plugged in. e. LOS is open collector output. Should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal. Mellanox Technologies...
  • Page 42: Appendix E Replacement Parts Ordering Numbers

    Power cord Type G for UK ACC000208 Power cord Type D for India ACC000209 Power cord Type I for China ACC000210 Power cord Type J for Switzerland ACC000211 Power cord Type B for Japan, ACC000212 Power cord Type I for Australia ACC000213 Mellanox Technologies...
  • Page 43: Appendix F Avertissements De Sécurité D'installation (French)

    6. Orages – dangers électriques Pendant un orage, il ne faut pas utiliser le matériel et il ne faut pas brancher ou débrancher les câbles. Mellanox Technologies...
  • Page 44 L’élimination de ce matériel doit s’effectuer dans le respect de toutes les législations et réglementations nationales en vigueur. 13. Codes électriques locaux et nationaux Ce matériel doit être installé dans le respect des codes électriques locaux et nationaux. Mellanox Technologies...
  • Page 45 Conformément à la Directive WEEE 2002/96/EC, les déchets d'équipements élec- triques et électroniques (EEE) doivent être triés et ne peuvent être éliminés avec les déchets ménagers. Veuillez disposer de ce produit et de tous ses composants de manière responsable et respectueuse de l’environnement. Mellanox Technologies...
  • Page 46: Appendix G Installation - Sicherheitshinweise (German)

    Anschlüsse angebracht bzw. davon getrennt werden. Lesen Sie die speziellen Warnungen und Anleitungen des Kabelherstellers. 7. Gafahr des elektrischen Schocks. Gafahr des elektrischen Schocks. Entferrnen des Netzsteckers elnes Netzteils spannungs- frei. Um alle Einhieten spannungsfrei zu machen sind die Netzstecker aller Netzteile zu entfernen Mellanox Technologies...
  • Page 47 Achtung – Nutzung von Steuerungen oder Einstellungen oder Ausführung von Proze- duren, die hier nicht spezifiziert sind, kann zu gefährlichem Strahlenkontakt führen.. Klasse 1 Laserprodukt und Referenzen zu den aktuellsten Lasterstandards : ICE 60 825-1:1993 + A1:1997 + A2:2001 und EN 60825-1:1994+A1:1996+ A2:2001 Mellanox Technologies...
  • Page 48 19. Zweipolige bzw. Neutralleiter-Sicherung im Netzteil Achtung: Zweipolige bzw. Neutralleiter-Sicherung im Netzteil. Netzstecker ziehen, um sicher- zustellen, daß keine Spannung am Gerät anliegt. Entfernen Sie alle Netzkabel vor dem Öffnen der Abdeckung dieses Produkts oder dem Berühren der Innenteile. Mellanox Technologies...
  • Page 49 >55 kgs 18 - 32 kgs Use enough people to safely lift this product. <40 lbs 70 - 121 lbs >121 lbs 40 - 70 lbs <18 kgs 32 - 55 kgs >55 kgs 18 - 32 kgs Mellanox Technologies...
  • Page 50: Appendix H Advertencias De Seguridad Para La Instalación (Spanish)

    6. Dos fusibles, uno en el polo y otro en el neutro Dos fusibles, uno en el polo y otro en el neutro. Quitar los cables de corriente antes de abrir la tapa de este producto o tocar cualquier componente interno. Mellanox Technologies...
  • Page 51 12. Eliminación de equipos La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales. 13. Códigos eléctricos locales y nacionales Este equipo se debe instalar conforme a los códigos eléctricos locales y nacio- nales. Mellanox Technologies...
  • Page 52 (EEE) se deben recolectar por separado y no se deben eliminar junto con residuos domésticos. Al deshacerse de este producto y de todas sus partes, hágalo de una manera respon- sable y respetuosa con el medio ambiente. Mellanox Technologies...
  • Page 53: Appendix I Special Regulations Regarding Finland, Sweden, Denmark, And Norway

    Do not connect this unit to any outlet that is not fully grounded! • Finland “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan” • Norway “Apparatet må tilkoples jordet stikkontakt” Unit is intended for connection to IT power systems for Norway only. • Sweden “Apparaten skall anslutas till jordat uttag.” Mellanox Technologies...