Eq (E Zone) - Midas PRO SERIES Owner's Manual

Pro series live audio systems
Hide thumbs Also See for PRO SERIES:
Table of Contents

Advertisement

Dynamics and EQ
Item
3
4
5
6
7
8
9
10
11

EQ (E zone)

For tonal control of the aux, matrix and master output signals, the output channel EQ
has the option of a six-band sweep parametric EQ (PEQ) or an assignable graphic EQ
(GEQ).
PEQ
The parametric EQ section (E zone) of the channel strip (mix and master bays) allows
tonal control of the input signal. The E zone contains all of the PEQ controls, along with
a shelving mode selection button and another set of band selection buttons.
All of the outputs, except returns, have six-band PEQs. Two of the six bands have three
shelving modes each, while another has just one. Any combination of the six bands can
be used to control the signal, although only one band can be adjusted in the E zone at
any time. However, the EQ processing area (GUI channel strip) displays four bands at
any time, and also has navigational controls.
The returns have a four-band PEQ, which is similar to that used on the inputs. For
information, see "EQ (E zone)" on page 299.
PRO Series Live Audio Systems
Owner's Manual
Control
threshold control
knob
comp/gate
up/down select
buttons
make up control
knob
KNEE switch
ratio/range/
[ratio] control
knob
attack control
knob
MODE switch
release control
knob
Meter
Function
Sets the signal level above which gain reduction
starts to be applied. Range is from -50dBu to
+25dBu.
These select buttons swap dynamic section control
from compressor to gate, and the reverse.
This compressor gain control compensates for the
reduced loudness of a compressed signal. Range is
from 0dB to 24dB.
This compressor control controls how compressor
starts to apply gain as the signal goes through the
threshold (see "Compressor graph" on page 292).
For more information, see Table "Compressor graph"
on page 292 and "Knee" on page 342.
This compressor control adjusts the amount of
compression applied to signals above threshold.
Range is from infinity (∞) to 1:1. When set to
maximum (1:1), sets compressor to limiter mode.
This compressor control adjusts the time it takes the
compressor to respond after an over-threshold signal.
Range is from 0.2ms to 20ms (milliseconds).
Selects compressor mode from the five compressor
types available (see "PRO Series compressor modes
(dynamic)" on page 341).
This compressor control adjusts the time it takes the
compressor to recover after programme material falls
back below threshold. Range is from 0.05s to 3.00s
(seconds).
Compressor 'gain reduction' meter.
321

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro3Pro6Pro9

Table of Contents