Page 1
Data Collector with GPS & Bluetooth OPL-9813 The OPL-9813 is a laser data collector featuring GPS (Global Positioning System) feature, Bluetooth 2.1 Specifications Manual communication and time stamp functionality.
Unless otherwise agreed in a written contract, all Opticon products are warranted against defects in materials and workmanship for two years after purchase. Opticon will repair or, at its option, replace products that are defective in materials or workmanship with proper use during the warranty period. Opticon is not liable for damages caused by modifications made by a customer.
Stored data can be sent to the host computer by IrDA Ver.1.2-compliant infra-red radiation communication (using a dedicated cradle). The OPL-9813 is a laser data collector with a GPS (Global Positioning System) feature and clock function. Those extra features of the OPL-9813 make it possible to add location data and a time stamp to scanned barcode data.
Opticon OPL-9813 Specifications Manual The OPL-9813 can use a variety of cradles: • CRD 9723 single bay cradle (1 x charging, 1 x communication) • CRD 9723 multi bay cradle (5 x charging, 1 x communication) • CRD 9723 multi bay cradle (5 x charging, 5 x communication) •...
Opticon OPL-9813 Specifications Manual 4.5. Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values: Incandescent light 3,000 lx Fluorescent light 3,000 lx Sunlight 50,000 lx Figure 1: Ambient Light Immunity...
Opticon OPL-9813 Specifications Manual 8.3. Scan Area and Resolution Depth of Field 8.3.1. The depth of field is measured from the edge of the data collector. The scanning range is within the circular arc centered on the scan origin. Figure 2: Depth of field...
Opticon OPL-9813 Specifications Manual Resolution Symbology Quiet Zone Digit 1.0 mm Code 39 25 mm 0.5 mm Code 39 18 mm 0.25 mm Code 39 10 mm 0.15 mm Code 39 7 mm Note: dirt or scratches on the mask will degrade scanning performance. Always handle the data collector carefully.
Opticon OPL-9813 Specifications Manual Skew Angle and Dead Zone 8.4.2. Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection) Figure 4: Skew and dead zone...
Opticon OPL-9813 Specifications Manual Tilt Angle 8.4.3. γ = ±20° Figure 5: Tilt angle Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: 90 mm from the edge of the data collector Pitch, Skew Angle Label: PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5...
The scanning range will vary according to the depth of field. 9. Interface Specifications 9.1. Bluetooth Module 9.1.1. The OPL-9813 is equipped with a low power fully certified Bluetooth module. Specifications 9.1.2. Bluetooth standard: 3 Bluetooth Class 2, Wireless range: 10m indoor (this may vary with the...
57.6 kbps, 38.4 kbps, 19.2 kbps, 9600 bps, 4800 bps, and 2400 bps. 9.3. GPS Module 9.3.1. The OPL-9813 is equipped with a GPS (Global Positioning System) module plus a compact patch antenna (15 mm X 15 mm) Receiving Frequency 9.3.2.
Opticon OPL-9813 Specifications Manual 10. Serial Number 10.1. Dimensions and location. Below is the product label with serial number. Figure 7: Name plate and serial number...
Bar code: Standard Code 39 plus human readable text printed below the bar code. Bar code height: 4mm Bar code data: The serial number. This should match that of the OPL-9813 in the box. The serial number consists out of 6 digits, starts with 000001 and is incremented with one every unit that is produced.
Opticon OPL-9813 Specifications Manual 11. Packaging Specifications 11.1. Individual Packaging Specification Put the data collector in a protective foam bag and place it in an individual packing box, then place the accessories into the box. Close the box and affix a label to the side of the box.
Opticon OPL-9813 Specifications Manual 11.2. Accessory Specification These accessories are enclosed in an individual package: • 1 hand strap 11.3. Collective Packaging Specification Put 150 individually packaged data collectors in a collective packing box. Dimensions (after assembly): 615 mm (W) by 520 mm (D) by 277 mm (H).
Opticon OPL-9813 Specifications Manual 12. Durability 12.1. Drop Test (without packaging) No malfunction occurred after the following drop test. Drop Test: Drop the data collector from a height of 150 cm onto a concrete floor. Each side of the data collector impacted the floor three times.
Opticon OPL-9813 Specifications Manual 13. Reliability MTBF (Mean Time Between Failures) of this product is 10,000 hours. 14. Regulatory Compliance 14.1. Laser Safety The data collector emits laser beams. JIS C6802: 2005: Laser class 2 IEC 825-1/EN 60825-1: Laser class 2 FDA CDRH Laser class II.
2002/95 EC. 14.4. State of California: Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate. To comply with California Perchlorate Best Practice Regulations and the Law for the Promotion of Utilization of Recyclable Resources (Japan), products that may contain Perchlorate...
Opticon OPL-9813 Specifications Manual 15. Safety Handle this product carefully. Do not deliberately subject it to any of the following. 15.1. Shock Do not throw or drop the data collector. Do not drop or put heavy items on this product.