Default Settings 2: Read Options, Trigger, Buzzer - Opticon OPV 1001 Specification Manual

Laser multi-barcode scanner opv 1001
Table of Contents

Advertisement

In the "Transmit CD" column, " " means "Transmit check digit" and "X" means
"Do not transmit check digit."
In the "Calculate CD" column, " " means "Calculate check digit" and "X"
means "Do not calculate check digit".
In the "Prefix" column, "-" means "There is no prefix setting".
For the Wedge and USB interfaces, there are no suffix settings.
The output contents for JAN ISBN code depends on the setting of EAN-13.
The output result is the same as transmitting EAN-13 twice.

10.3. Default Settings 2: Read Options, Trigger, Buzzer

Item
Setting the number of characters
Read mode
Multiple read reset time
Add-on wait mode
Multiple column read
Redundancy
Intercharacter gap check (NW-7)
Read time
Buzzer duration
Buzzer tone
Buzzer loudness
Good read LED
Set minimum length
Default Setting
Fixed length OFF all codes
Multiple read
500 ms
500 ms
Disable
Read 2 times, redundancy = 1
Within 0.5 characters
2 seconds
100 ms
2.6 kHz
Maximum
Indicator duration 200 ms
Code 11: 1 character
Code 39: 1 character
Code 93: 1 character
Code 128: 1 character
Codabar/NW-7: 5
characters
EAN 128: 1 character
IATA: 5 characters
30
Opticon
OPV 1001
Specifications Manual
Industrial 2of5: 5 characters
Interleaved 2of5: 6
characters
MSI/Plessey: 3 characters
UK/Plessey: 2 characters
S-Code: 5 characters
Telepen: 5 characters