Item
Setting the number of characters
Read mode
Multiple read reset time
Add-on wait mode
Multiple label read
Multiple column read
Redundancy
Default option
([X0] setting)
Other options
([X1 .. X3] setting)
([BS .. BW] setting)
Trigger switch
Trigger repeat
Auto trigger
Read time
Margin check
Buzzer duration
Buzzer tone
Buzzer loudness
Buzzer transmission
Startup buzzer
Good read LED
Default Setting
Fixed length OFF all codes
Multiple read
500 ms
500 ms
Disable
Disable
Read 1 times, redundancy = 0
Read n times, redundancy = n+1 for the following
symbologies and lengths:
● Code 11 with length <= 5
● Code 39 with length <= 5
● IATA,Industrial 2of5, Interleaved 2of5 with length <= 8
● Matrix 2of5 (& Chinese Post), Scode with length <= 8
● MSI/Plessey with length <= 4
● NW-7 (Codabar) with all lengths
Enable
Disable
Disable
2 seconds (when trigger enabled)
Normal
50 ms
Single tone (3 kHz)
Maximum
Before transmission
Enable
Indicator duration 200 ms