Troubleshooting; Table 6-1, Remote Control Troubleshooting Guide - Magnum Energy ME-RC Owner's Manual

Hide thumbs Also See for ME-RC:
Table of Contents

Advertisement

.0 Troubleshooting

The remote may not be functioning correctly, use the following table to help
find a solution.
Table -, Remote Control Troubleshooting Guide
Symptom
Display shows
unrecognizable
letters or
symbols.
Display shows
"fatal error"
or "illegal
address".
LCD text
display is
locked-up,
pushing any
pushbutton
has no
response
- may show
"revision" or
"connecting".
LEDs and
backlight are
off.
Remote is
non-functional
(no lights, no
text on LCD
display and no
response when
pressing any
pushbutton).
©2009 Magnum Energy Inc.
Possible Cause
Static electricity
may have been
discharged into the
LCD display
The remote's internal
data addressing was
unrecognizable.
RJ11 connections on
communication cable
are not making a
good connection
Remote not getting
sufficient power from
inverter.
Remote is in Power
Saver mode.
Communication
cable bad or not
correctly connected
to remote port on
inverter.
Inverter is not
connected to
batteries.
.0 Troubleshooting
Solution
Refresh Display: press and
hold the SELECT button for 10
seconds.
Reset remote: disconnect
remote communications cable
from inverter for 5 seconds and
reconnect (see figure 2-2).
Reset remote: 1) disconnect
remote cable from inverter for 5
seconds and reconnect; 2) check
RJ11 cable connection on back
of remote (see figure 2-2).
Important: ensure the RJ11
connector is pushed into the
correct port; you should feel/
hear "click" when the connection
is made.
Ensure inverter batteries are
connected and inverter is
operating correctly; inverter
should be able to invert and
power AC loads from batteries
(ensure no AC power is
connected to the inverter AC
inputs).
Press any button to reactivate
remote (or turn Power Saver
mode Off).
Check communications cable
from inverter to remote;
ensure: 1) it is connected to
the REMOTE port, 2) the correct
communications cable is used
(a 4-conductor telephone
cable may be substituted to
determine if cable is good).
Ensure inverter batteries are
connected and inverter is
operating correctly without
any AC power connected (can
invert and power AC loads from
batteries).