Troubleshooting; Table 6.1, Remote Troubleshooting - Magnum Energy ME-MR Series Owner's Manual

Inverter remote control
Table of Contents

Advertisement

Operation

6.0 Troubleshooting

The remote may not be functioning correctly, use the following table to help
fi nd a solution.

Table 6.1, Remote Troubleshooting

Symptom
Possible Cause
LCD text
RJ11 connections on
display is
communication cable
locked-up,
are not making a
pushing any
good connection
pushbutton
has no
response
- may show
"revision" or
"connecting".
Remote not getting
suffi cient power from
inverter.
LEDs and
Remote is in Power
backlight are
Saver mode.
off.
Remote is
Communication
non-functional
cable bad or not
(no lights, no
correctly connected
text on LCD
to remote port on
display and no
inverter.
response when
pressing any
pushbutton).
Inverter is not
connected to
batteries.
34
Solution
Reset remote: 1) disconnect
remote cable from inverter for 5
seconds and reconnect; 2) check
RJ11 cable connection on back
of remote (see fi gure 2-2).
Important: ensure the RJ11
connector is pushed into the
correct port; you should feel/
hear "click" when the connection
is made.
Ensure inverter batteries are
connected and inverter is
operating correctly; inverter
should be able to invert and
power AC loads from batteries
(ensure no AC power is
connected to the inverter AC
inputs).
Press any button to reactivate
remote (or turn Power Saver
mode Off).
Check communications cable
from inverter to remote;
ensure: 1) it is connected to
the REMOTE port, 2) the correct
communications cable is used
(a 4-conductor telephone
cable may be substituted to
determine if cable is good).
Ensure inverter batteries are
connected and inverter is
operating correctly without
any AC power connected (can
invert and power AC loads from
batteries).
©2009 Magnum Energy Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me-mr25

Table of Contents