5.3 System Status Messages

The remote control uses the top line of the LCD display to show the inverter/
chargers current operation by displaying a status
will show the inverter/ charger's operating modes and the available status
messages under each mode. Use these status messages along with the
Status LED's to determine the inverter/charger's current operating status
and to help troubleshoot the system if a fault occurs.
There are three operating modes of the inverter/charger:
• Inverter Mode

5.3. Inverter Mode Messages

The inverter/charger will be in the Inverter Mode when AC power (shorepower/util-
ity or generator) is not available or unacceptable to the inverter/charger's input.
The Inverter Mode messages are Off, Searching and Inverting.
PWR
Off
FAULT
Settings/Info...
CHG
INV

Figure 5-2, Off Mode

Off – This message tells you that there is no AC available on the
inverter's AC output. The inverter function is off and there is no utility/shore
or generator power AC sensed on its input.
PWR
Searching
FAULT
Settings /Info...
CHG
INV

Figure 5-3, Searching Mode

Searching – The inverter is in the Search mode, which means the
AC loads on the inverter output are less than the SETUP: 01 Search Watts
setting. The search mode function is used to reduce the inverter draw from
the battery and may be turned off at any time if you want full inverter output
voltage available at all times (see the SETUP: 01 section).
PWR
Inverting
FAULT
Settings/Info...
CHG
INV

Figure 5-4, Inverting Mode

Inverting - The inverter is providing AC voltage on its output by
inverting power from the batteries.
©2009 Magnum Energy Inc.
• Charger Mode
Off appears on the LCD; all LED's
are off.
Searching appears on the LCD. The
PWR (green) LED is on solid and the
INV (green) LED slowly flashes. The
FAULT (red) and CHG (green) LED's
are off.
Inverting appears on the LCD. The
PWR (green) and INV (green) LED's
are on solid. The FAULT (red) and
CHG LED's are off.