Troubleshooting; Table 6-1, Remote Control Troubleshooting Guide - Magnum Energy ME-ARC50 Owner's Manual

Me-arc series. advanced remote control. version 4.0 or higher: with ags, bmk, acld, and pt info
Hide thumbs Also See for ME-ARC50:
Table of Contents

Advertisement

6.0

Troubleshooting

The remote may not be functioning correctly, use the following table to help fi nd a solutions.

Table 6-1, Remote Control Troubleshooting Guide

Symptom
Display shows
unrecognizable
letters or symbols
LCD text display is
locked-up, pushing
any button has no
response
LEDs and backlight
are off
Remote is non-
functional (no
lights, no text on
LCD display, and
no response when
pressing any button)
© 2014 Magnum Energy, Inc.
Possible Cause
Static electricity may
have been discharged
into the LCD display.
RJ11 connections on
communication cable
are not making a
good connection.
Remote not getting
suffi cient power from
inverter.
Remote may be in
Power Save mode.
Communication cable
is bad or not correctly
connected to the
Remote port on the
inverter.
Inverter is not
connected to the
batteries.
Solution
Refresh Display: Press and hold the
SELECT knob for 10 seconds.
Reset remote: 1) Disconnect remote
cable from inverter for 5 seconds and
reconnect;
2) Check RJ11 cable connection on back of
remote (Figure 2-2).
Important: Ensure the RJ11 connector is
pushed into the correct port. You should
feel/hear a "click" when the connection is
made.
Ensure inverter batteries are connected
and the inverter is operating correctly;
the inverter should be able to invert and
power AC loads from the batteries (ensure
no AC power is connected to the inverter
AC inputs).
Press any button to reactivate the remote
(or turn Power Save mode Off).
Check communications cable from
inverter to remote; ensure: 1) it is
connected to the Remote port, 2) the
correct communications cable is used
(a 4-conductor telephone cable may be
substituted to determine if the cable is
good).
Ensure the inverter batteries are
connected and the inverter is operating
correctly without any AC power connected
(can invert and power AC loads from
batteries).
Troubleshooting
Page 56

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents