Performing An Inverter Reset; Powering-Down The Inverter; Figure 6-1, Performing An Inverter Reset - Magnum Energy ME-RC Owner's Manual

Hide thumbs Also See for ME-RC:
Table of Contents

Advertisement

.2 Performing an Inverter Reset

Press and hold the Power ON/OFF pushbutton (see figure 6-1) for
approximately fifteen (15) seconds until the Charging/Inverting Status LED
comes on and flashes rapidly; once the rapid flashing has begun, release the
Power ON/OFF pushbutton. The Status LED will go off after the pushbutton
is released.
After the inverter reset is completed, press the ON/OFF pushbutton to turn
the inverter ON.
Some older inverter models do not allow an inverter reset, if the inverter reset
fails, you will need to power-down the inverter using the procedure below.
In either case, if an "internal fault" does not clear, the inverter will require
repair at an authorized service facility.
Info: The Power ON/OFF pushbutton is a small momentary type
switch which operates by lightly pressing and releasing.
Info: All adjustable inverter/charger settings in the ME-RC (except
for the SHORE: Shore Max and SETUP: 08 Screen Setup settings -
which revert back to default) are saved in non-volatile memory and
are preserved until changed - even if an inverter reset is performed
or if all power to the remote or inverter is removed.

Figure 6-1, Performing an Inverter Reset

.3 Powering-down the Inverter

Perform the following steps to power-down the inverter:
1.
Remove all AC power (utility or generator power) to the inverter.
2.
Disconnect the positive battery cable to the inverter.
3.
Ensure the inverter and remote control are disconnected from all AC
and DC power (the remote display will be blank).
After the inverter has been disconnected from all power for 30 seconds, re-
connect the positive battery cable and resume operation.
Info: There may be a momentary spark when the positive battery
cable is connected to the inverter's terminal; this is normal and in-
dicates that the inverter's internal capacitors are being charged.
©2009 Magnum Energy Inc.
.0 Troubleshooting
1 . P re ss a n d h o ld th e P o w e r O N/
O FF p u sh -b u tto n fo r 1 5 se co n d s
2 . W a tch th e C h a rg in g/ In ve rtin g
S ta tu s L E D , a fte r a p p ro xim a te ly 1 5
se co n d s it sh o u ld co m e o n a n d
fla sh ra p id ly to in d ica te th e in ve rte r
h a s re se t. Th e S ta tu s L E D w ill g o
o ff a fte r th e p u sh b u tto n is
re le a se d.