Led Operation; Autocross Feature For Twisted Pair Connections; Configuration - IMC Networks IE-MultiWay Operation Manual

Media/mode converter gigabit ethernet
Hide thumbs Also See for IE-MultiWay:
Table of Contents

Advertisement

To log on through the serial port, set the computer/terminal for VT-100 emulation,
with: 38.4K baud, 8 data bits, 1 stop bit, no parity, no FlowControl.

LED Operation

Each IE-MultiWay includes SFP and RJ-45 LEDs.
SFP LED functions are as follows:
FLT
Glows amber when a fault is detected.
LNK
Glows green with a valid optical link.
ACTIVE
Glows green when the port is active
OFF when SFP is in standby (does not indicate activity)
OAM
Glows green when an active OAM AH channel is established.
RJ-45 LED functions are as follows:
LNK/ACT
Glows green when a link is established on the TX port; blinks green
when activity is detected on the TX port.
FDX
Glows amber when an FDX link is established on the TX port.
Not lit for HDX.

Autocross Feature for Twisted Pair Connections

All fixed twisted pair ports on the IE-MultiWay include AutoCross, a feature that
automatically selects between a crossover workstation and a straight-through
connection depending on the connected device.

Configuration

The IE-MultiWay includes many features that are configurable via a serial/Telnet
session (CLI) or through iView² (SNMP Management view or iConfig view).