Sampling frequency select switch
Set this to the sampling frequency that is selected on your recording sequencer software.
* After you change the position of the sampling frequency select switch, you will need to disconnect and
reconnect the UA-1EX.
Recording source select switch
Set this to ANALOG.
* Turn down the volume of your connected monitor speakers (or similar equipment) before you change the
setting of the recording source select switch.
Input volume
Use this to adjust the input level.
Other notes
• Howling could be produced depending on the location of microphones relative to speakers. This
can be remedied by:
1. Changing the orientation of the microphone(s).
2. Relocating microphone(s) at a greater distance from speakers.
3. Lowering volume levels.
• The UA-1EX is compatible with plug-in powered mics (miniature condenser mics designed for
connection to a computer's mic input or to the recording jack of an MD (Mini Disc) recorder).
You must use a plug-in powered mic for connection to the mic input jack (plug-in powered mic).
The circuit may be damaged if you connect a conventional stereo mini-type plug or an
unsupported type of mic.