Figure 3.17: Smtp Configuration - Advantech EKI-7659CPI User Manual

8+2g combo ports industrial poe managed redundant gigabit ethernet switch
Table of Contents

Advertisement

Click Apply .
System Event Log - Event Configuration
You can select the 'Syslog' and 'SMTP' events for each port. When selected events occur, the system
will send out the log information to the system log server. After configuring, Click Apply .
System event selection: 4 selections – Device cold start, Device warm start, SNMP Authentication
Failure, and X-ring topology change. Mark the checkbox to select the event. When selected events
occur, the system will issue the logs.
Device cold start: when the device executes cold start action, the system will issue a log
event.
Device warm start: when the device executes warm start, the system will issue a log event.
Authentication Failure: when the SNMP authentication fails, the system will issue a log event.
X-ring topology change: when the X-ring topology has changed, the system will issue a log
event.
Port event selection: select the syslog and SMTP events for each port. It has 3 selections—Link
Up, Link Down, and Link UP & Link Down. Disable means no event is selected.
Link UP: the system will issue a log message when port connection links up only.
Link Down: the system will issue a log message when port connection links down only.
Link UP & Link Down: the system will issue a log message when port connection is up and
down.

Figure 3.17: SMTP Configuration

47
Chapter3