AXIS 5400+ User's Manual
String Substitutions
Example:
3. Enter the string 1B 26 6C 34 48 in the String Before Print Job
text field.
4. Enter the string 1B 26 6C 31 48 in the String After Print Job
text field.
5. Click the OK button when finished.
The string substitution function performs search and replace
operations on the print data. The primary application is to replace
printer control commands. Up to twenty string substitutions may be
specified individually for each logical printer.
All strings must be entered as hexadecimal byte values, and each match
and substitute string must be preceded by a count byte.
You substitute command strings by editing the String Substitutions
(PRx_STR) parameter.
Assume that you want to replace the UNIX New Line (hex
an ASCII NewLine (hex
Follow the instructions below to substitute command strings:
1. From the print server's internal web page, select Admin | Logical
Printer Settings.
2. Select the PR1 tab.
3. Enter the string 01 0A 02 0D 0A in the String Substitutions text
field.
Hex Code
01
0A
02
0D 0A
4. Click the OK button when finished.
Section 8: Setting Up - UNIX
) for logical printer PR1.
0D 0A
Explanation
length of the string you want to re-
place
the string you want to replace
length of the substitute string
the substitute string