Display Intensity; Fan Speed; Serial Number; Sw Version - AJA Ki PRO rack Operation Manual

1 ru rack-mounted digital video recorder
Table of Contents

Advertisement

70.2 DISPLAY
INTENSITY

70.3 FAN SPEED

80.1 SERIAL NUMBER

80.2 SW VERSION

91.1 RECALL PRESET

92.1 STORE PRESET

99.0 FACTORY RESET

Ki Pro Rack v4.2
NOTE:
The screensaver will not appear if an active transport function is underway (Play, Record, etc.).
This parameter determines the brightness of the alphanumeric VFD display and front
panel backlit buttons. These are the available options:
variable
(Default: 6)
This parameter determines the speed of Ki Pro Rack's internal cooling fan. In some
environments where audio recording is occurring close to the Ki Pro Rack unit, it may be
desirable to set the fan speed to "QUIET RECORD" for optimum quiet operation. These are
the available options:
NORMAL (default)
QUIET RECORD
QUIET AUTO
NORMAL AUTO
This parameter displays this Ki Pro Rack's unique serial number.
This parameter displays Ki Pro Rack's software version level.
This parameter recalls the Ki Pro Rack to a previously saved preset configuration stored
using parameter 92.1.
Use the ADJUST buttons to set the number of the Preset register you wish to recall. To
recall, press the SELECT up (^) button, and then press the ADJUST up (^) button. The
message [COMPLETE] is displayed after a successful recall.
This parameter saves a preset configuration to the selected storage register. Use the
ADJUST buttons to set the number of the Preset register.
To store, press the SELECT up (^) button, and then press the ADJUST up (^) button. The
message [COMPLETE] is displayed after a successful store.
Selecting this parameter and then pressing the ADJUST (up) button for 2 seconds recalls
Ki Pro Rack's factory default settings.
Caution!
Selecting this parameter and recalling factory defaults will overwrite the current
settings (with the exception of network settings, which are retained).
Recalling factory defaults does not affect these settings: Encode Mode, Encode Type, IP
Config, IP Address, Subnet Mask, Default Gateway, System Name, or Date and Time. To
clear the network settings and recall factory defaults, hold down both the Adjust (up)
and Adjust (down) buttons at the same time.
NOTE:
To set a single parameter to its factory default value, go to that parameter and hold down
both the Adjust (up) and Adjust (down) buttons at the same time.
Using the Adjust buttons, you can dim or brighten the
alphanumeric display and activity indicator LEDs in steps
from 1 (dim) to 8 (brightest)
Fan runs at normal fixed speed for optimum cooling.
Fan runs at a fixed slower speed for optimum quiet.
Fan runs at normal speed until recording begins, then ramps
down to a slower speed for optimum quiet.
Fan runs at variable speeds for optimum cooling.