Fujitsu ETERNUS DX80 S2 User Manual page 106

Disk storage system
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.1 Message Format
No.
2
Time stamp
3
Host name
4
Program or process
5
CM No. and
message type
6
Message serial
number
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
Item
The local time when the event is detected is output in the following format:
For RFC3164
Mmm dd hh:mm:ss
-
Mmm
Abbreviation of each month (Jan - Dec)
-
dd
Date. If the date is a single digit, a blank is output before the date number.
-
hh:mm:ss
Local time. "hh" indicates the hour (00 – 23), "mm" indicates minutes (00 – 59),
and "ss" indicates seconds (00 – 59). A blank follows this item.
For RFC5424
yyyy-mm-ddThh:mm:ss±hh:mm
-
yyyy
The year is displayed with four digits.
-
mm
The month is displayed with two digits (01 – 12).
-
dd
The date is displayed with two digits (01 – 31). "T" follows this item.
-
hh:mm:ss
Local time. "hh" indicates the hour (00 – 23), "mm" indicates minutes (00 – 59),
and "ss" indicates seconds (00 – 59). A blank follows this item.
-
±hh:mm
Time differences between the local time and the GMT. The value for the time
zone specified in the date and time setting of ETERNUS Web GUI or ETERNUS CLI
is displayed. "hh" indicates the hour (00 – 23) and "mm" indicates minutes (00 –
59). A blank follows this item.
The IP address of the sender port (MNT or RMT) for the ETERNUS DX Disk storage system
is output in IPv4 or IPv6 format:
IPv4
xxx.xxx.xxx.xxx
The IPv4 address is output based on the "IETF STD13, RFC 1035" specification.
IPv6
xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
The IPv6 address is output based on the "RFC 4291" specification.
A blank follows this item.
The name of the program or process that generates the message is output.
"Storage" is output for all the messages.
For the "RFC3164" format, a colon [:] and then a blank, which indicate the end of the TAG
field, follow this item.
For the "RFC5424" format, a blank follows this item.
The CM number of the controller that outputs the message and the message type are
output.
"0" or "1" is output according to the message for the CM No.
"0" is output for the message type.
For the "RFC3164" format, a comma and then a blank follow this item.
For the "RFC5424" format, a blank follows this item.
The message serial number is displayed for each controller.
For the "RFC3164" format, a comma and then a blank follow this item.
For the "RFC5424" format, a blank, a hyphen, and a blank follow this item in this order.
Copyright 2013 FUJITSU LIMITED
Description
106
P3AM-4842-12ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents