Fujitsu ETERNUS DX80 S2 User Manual page 146

Disk storage system
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Event type
code
I 01020020
I 01030010
I 01030020
I 01050010
I 01050020
I 01050030
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapLink
TrapItemId
No.
StatusInfo
9
9
9
9
9
9
146
Copyright 2013 FUJITSU LIMITED
Upper: Message
Middle: Detail information
Lower: Description
%d
hot spare(s) released
&a
&b
&c
Enclosure=
Slot=
Type=
&d
RAID_Group_No=
RAID_Group_Name=
%d
hot spares are deleted.
%d
: Quantity
&a
: DE-ID ("00" for a controller enclosure)
&b
: Slot number
&c: Type (Global or Dedicated)
&d
: RAID group number (only for Dedicated
Hot Spares)
&e
: RAID group name (only for Dedicated
Hot Spares)
%d
volume(s) created
For Standard volumes, SDVs, or SDPVs
&a
&b
&c
No=
Name=
Type=
Capacity=
&e
RAID_Group_No=
RAID_Group_Name=
For TPVs
&a
&b
&c
No=
Name=
Type=
Capacity=
&g
&h
Pool_No=
Pool_Name=
%d
volumes are created.
%d
: Quantity
&a
: Volume number
&b
: Volume name
&c: Volume type
&d
: Capacity
&e
: RAID group number (only for Standard/
Open volume, SDV, or SDPV)
&f
: RAID group name (only for Standard/
Open volume, SDV, or SDPV)
&g
: TPP number (only for Standard/Open
volume or TPV)
&h
: TPP name (only for Standard/Open
volume or TPV)
%d
volume(s) deleted
&b
No=&a Name=
%d
volumes are deleted.
This message is not notified when the deletion
reservation function is used to delete the SDPV.
%d
: Quantity
&a
: Volume number
&b
: Volume name
$a
Power on completed (
)
Detail information is not displayed.
The device status is changed to Ready.
$a
xx
xx
xxxx
: V
L
-
(Firmware version)
Shutdown started
Detail information is not displayed.
Device shutdown has started.
Controller firmware updated (
$a
)
Detail information is not displayed.
Controller firmware version is updated.
$a
xx
xx
xxxx
: V
L
-
(Firmware version)
Remarks
These messages are
notified when
"Added/Released
&e
Hot Spare" is
enabled for
Informational Level
in the event
notification setting.
These messages are
notified when
"Operated Volume"
&d
is enabled for
&f
Informational Level
in the event
&d
notification setting.
These messages are
notified when
"Power off/on Apply
Firmware" is
enabled for
Informational Level
in the event
notification setting.
P3AM-4842-12ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents