Reaction Checked-Element Probe-Fail (For Trigger) - HP 6125XLG Command Reference Manual

Blade switch network management and monitoring
Table of Contents

Advertisement

Examples
# Create reaction entry 1 for monitoring the probe failures in ICMP echo operation. Before the NQA
operation starts, the initial state of the reaction entry is invalid. If the total number of probe failures
exceeds 10 (included), the state of the entry is set to over-threshold. If it is below the threshold, the state
of the entry is set to below-threshold. Once the state of the reaction entry changes, the result is displayed
on the terminal.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] reaction 1 checked-element probe-fail threshold-type
accumulate 10 action-type none
# Create reaction entry 2 for monitoring the probe failures in ICMP echo operation. Before the NQA
operation starts, the initial state of the reaction entry is invalid. If the number of consecutive probe failures
exceeds 10 (included), the state of the entry is set to over-threshold. If it is below the threshold, the state
of the entry is set to below-threshold. Once the state of the reaction entry changes, the result is displayed
on the terminal.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] reaction 2 checked-element probe-fail threshold-type
consecutive 10 action-type none

reaction checked-element probe-fail (for trigger)

Use reaction checked-element probe-fail to configure a reaction entry for monitoring probe failures.
Use undo reaction to remove the specified reaction entry.
Syntax
reaction item-number checked-element probe-fail threshold-type consecutive consecutive-occurrences
action-type trigger-only
undo reaction item-number
Default
No reaction entry for monitoring probe failures is configured.
Views
ICMP echo operation view, UDP echo operation view
Predefined user roles
network-admin
Parameters
item-number: Assigns an ID to the reaction entry, in the range of 1 to 10.
threshold-type: Specifies a threshold type.
consecutive consecutive-occurrences: Checks the maximum number of consecutive probe failures, in the
range of 1 to 16.
action-type: Specifies what action to be triggered.
trigger-only: Triggers other modules to react to certain conditions.
133

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents