Alarm Input/Output Signal - JVC VN-H657WPBU Instructions Manual

Jvc hd ip ptz camera
Hide thumbs Also See for VN-H657WPBU:
Table of Contents

Advertisement

Alarm Input/Output Signal

Alarm Input Signal
Connect to sensors such as infrared sensors, door
sensors, metal sensors and manual switches.
To prevent noise from entering the internal
0
circuit, supply non-voltage contact signal to the
alarm input signal.
Memo :
You can configure whether to set the alarm when
0
the contact is short (MAKE) or open (BREAK) in
the [Alarm] page of the [Advanced Settings]
page.
(A p.56 [[Alarm] Page] )
Apply such that the alarm signal continues for at
0
least 500 ms. The alarm signal may not be
recognized if it is less than 500 ms.
Note :
Do not supply voltage.
0
INPUT
COM
.
Rating
Low-level terminal current : 1 mA and below
High-level terminal voltage : 3.3 V
Alarm Output Signal
Connect to alarm devices such as alarm, indicator,
light or buzzer.
Alarm output signal is an open collector output
0
insulated with photo coupler.
Memo :
You can select whether to set the contact to
0
short (Make) or open (Break) during an alarm in
the [Alarm] page of the [Advanced Settings]
page.
(A p.56 [[Alarm] Page] )
Note :
As this terminal is polarized, be sure to connect
0
it such that the voltage of the OUTPUT output is
higher than that of the COM output.
It will be damaged if reverse voltage is supplied.
0
22
.
Rating
Max. applied voltage : DC 20 V
Max. driving current
Alarm Input/Output Signal
OUTPUT
COM
: 25 mA
19