In rare cases an N-Ring can have a "Partial Fault". An example of this is to have a break in just one fiber in
a duplex channel fiber pair. The screenshot below shows N-Ring Manager Status when a „Higher‟ N-Ring
Port (GB2 or FX2) is not receiving self health frames all the way around the N-Ring, though the other (low
GB1/FX1) N-Ring port is:
N-Ring Partial Fault (GB2 is not receiving self health from GB1)
Switch is an N-Ring Manager, using N-Ring Aging Time = 20 seconds
Refresh every
0 Active Members Detected In Current N-Ring (0 reporting)
Switch No MAC Address
RM
00:07:af:00:b1:40
The screenshot below shows N-Ring Manager Status when a „Lower‟ N-Ring Port (GB1 or FX1) is not
receiving self health frames all the way around the N-Ring, though the other (high GB2/FX2) N-Ring port
is:
N-Ring Partial Fault (GB1 is not receiving self health from GB2)
Switch is an N-Ring Manager, using N-Ring Aging Time = 20 seconds
Refresh every
0 Active Members Detected In Current N-Ring (0 reporting)
Switch No MAC Address
RM
(Revised 2011-07-21)
N-Ring Status View
6
secs.
IP Address
192.168.1.135 255.255.255.0 N-TRON Switch
N-Ring Status View
6
secs.
IP Address
00:07:af:00:b1:40
192.168.1.135 255.255.255.0 N-TRON Switch
Update
Pause
Subnet Mask
Name
Update
Pause
Subnet Mask
Name
Print...
Ports
GB2
GB1
Print...
Ports
GB2
GB1
page 69 of 152

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7014fx27014fxe2

Table of Contents