APPLYING POWER (Side View)
Note: Only 1 power supply must be connected to power for minimal operation. For redundant power
operation, V
and V
1
2
current from both sources simultaneously. Use 16-28 gauge wire when connecting to the power supply.
Recommended 24V DC Power Supplies, similar to: N-Tron‟s P/N NTPS-24-3
 Input AC 115/230V
 Output DC 24-28V
 Output Current 3A @ 24V
(Revised 2011-07-21)
inputs must be connected to separate DC Voltage sources. This device will draw
2.6A @ 28V
 Unscrew & Remove the DC Voltage Input
Plug from the Power Input Header
 Install the DC Power Cables into the Plug
(observing polarity).
 For best results keep the power cable length
to a maximum of one (1) meter.
 Plug the Voltage Input Plug back into the
Power Input Header.
 Tightening torque for the terminal block
power plug is 0.5 Nm/0.368 Pound Foot.
 Verify the Power LED stays ON (GREEN).
 Power 30W
 35 mm DIN-Rail Mountable
 Dimensions: 45X75X91 mm