Configuring Power Policing - Cisco Catalyst 2960-XR Configuration Manual

Switch interface and hardware component
Hide thumbs Also See for Catalyst 2960-XR:
Table of Contents

Advertisement

Configuring PoE
SUMMARY STEPS
1. configure terminal
2. interface interface-id
3. power inline police [action{log | errdisable}]
4. exit
5. Use one of the following:
6. exit
7. Use one of the following:
DETAILED STEPS
Command or Action
Step 1
configure terminal
Example:
Switch# configure terminal
Step 2
interface interface-id
Example:
Switch(config)# interface
gigabitethernet2/0/1
Step 3
power inline police [action{log | errdisable}]
Example:
Switch(config-if)# power inline police
OL-29420-01
• errdisable detect cause inline-power
• errdisable recovery cause inline-power
• errdisable recovery interval interval
• show power inline police
• show errdisable recovery
Catalyst 2960-XR Switch Interface and Hardware Component Configuration Guide, Cisco IOS Release 15.0(2)EX1
Purpose
Enters global configuration mode.
Specifies the physical port to be configured, and enter interface
configuration mode.
If the real-time power consumption exceeds the maximum power
allocation on the port, configures the switch to take one of these actions:
• power inline police—Shuts down the PoE port, turns off power
to it, and puts it in the error-disabled state.
Note
You can enable error detection for the PoE error-disabled cause
by using the errdisable detect cause inline-power global
configuration command. You can also enable the timer to
recover from the PoE error-disabled state by using the
errdisable recovery cause inline-power interval interval
global configuration command.
• power inline police action errdisable—Turns off power to the
port if the real-time power consumption exceeds the maximum
power allocation on the port.

Configuring Power Policing