Configuring Power Policing
Command or Action
Step 4
exit
Example:
Switch(config-if)# exit
Step 5
Use one of the following:
• errdisable detect cause inline-power
• errdisable recovery cause inline-power
• errdisable recovery interval interval
Example:
Switch(config)# errdisable detect cause
inline-power
Switch(config)# errdisable recovery cause
inline-power
Switch(config)# errdisable recovery
interval 100
Step 6
exit
Example:
Switch(config)# exit
Step 7
Use one of the following:
• show power inline police
• show errdisable recovery
Example:
Switch# show power inline police
Switch# show errdisable recovery
Catalyst 2960-XR Switch Interface and Hardware Component Configuration Guide, Cisco IOS Release 15.0(2)EX1
94
Purpose
• power inline police action log—Generates a syslog message
while still providing power to the port.
If you do not enter the action log keywords, the default action shuts
down the port and puts the port in the error-disabled state.
Returns to global configuration mode.
(Optional) Enables error recovery from the PoE error-disabled state,
and configures the PoE recover mechanism variables.
By default, the recovery interval is 300 seconds.
For interval interval, specifies the time in seconds to recover from the
error-disabled state. The range is 30 to 86400.
Returns to privileged EXEC mode.
Displays the power monitoring status, and verify the error recovery
settings.
Configuring PoE