3 - 22

3.15 TRACE STORAGE

In the digital mode you not only have the ability to store traces on the screen
(using the RUN/STOP key), but also to store traces in memory for later use.
Figure 3.12
Digital memory setup
Store traces on screen:
Step 1
Press AUTOSET.
Step 2
Make sure that the scope is in the digital mode. If not, press the
ANALOG key to enter the digital mode.
Step 3
With the RUN/STOP key, new acquisitions are stopped and the display
is frozen. Removing the input signal or pressing a key has no effect on
the display. Stopping the acquisition is very useful to do measurements
on the signal or to make a hard copy.
Step 4
Press the RUN/STOP key to reactivate the acquisition.
Store traces in memory:
Step 5
For this step-by-step introduction you will first clear all memory
locations so that all unnecessary traces are removed.
- press the SAVE menu key.
- select CLEAR & PROTECT.
- select CLEAR ALL.
- in the confirm menu, select YES.
Sometimes there will be a second confirm menu. Select YES again to
clear protected traces as well.
Press the TEXT OFF key to turn the menu off.
1
2
3
4
GETTING STARTED
ANALOG
SAVE
RECALL
RUN/STOP
ST6691