Fluke CombiScope PM3370B User Manual page 214

Autoranging combiscope instrument
Hide thumbs Also See for CombiScope PM3370B:
Table of Contents

Advertisement

5 - 94
-
oversh (OVERSHOOT)
Measures the overshoot (in %), related to the amplitude of the signal. There are
two types of overshoot: rising overshoot and falling overshoot (undershoot).
rising oversh =
falling oversh =
-
presh (PRESHOOT)
Measures the preshoot (in %), related to the amplitude of the signal. There are
two types of preshoot: rising preshoot and falling preshoot.
rising presh =
falling presh =
It is possible to perform measurements on the part of the waveform between the
two cursors. This function is called cursor limited measurements and is turned on
via the key sequence MEASURE >> CURSOR LIMIT & STATIST >> CURSOR
LIMITED yes. Cursor operation is done via the TRACK and controls and via the
CURSOR menu.
Results of the measurements MEAS1 and MEAS2 are displayed in the top left
corner of the screen. When you press the key sequence MEASURE >> CURSOR
LIMIT & STATIST >> STATIST on, the screen displays three values per MEAS
function. These values are measured over the total number of acquisitions for that
particular measurement and are updated instantly. The statistic measurement
values are as follows:
-
absolute minimum value
-
absolute maximum value
-
mean value
max (of 1st rising slope) -high
high - low
low - min (of 1st falling slope)
high - low
low - min (of 1st rising slope)
high - low
max (of 1st falling slope) -high
high - low
FUNCTION REFERENCE
100%
*
100%
*
100%
*
100%
*

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents