Cartridge Access Ports

Cartridge Access Ports
The cartridge access ports (CAPs) can be used to add cartridges to the library, or
remove cartridges from the library without interrupting normal robotic operation.
The CAP in the Base Module has one five-cell magazine.
The CAP in the Drive Expansion Module has two five-cell magazines.
Although the CAPs are not physically connected, they are logically connected. If any of
the CAPs are open, the CAP LED on the keypad will be on, alerting the operator to take
action to close the CAP. If all of the CAPs are closed, the CAP LED will be off.
You can use the keypad on the robotics unit to issue a command for the robot to unlock
the CAP.
The CAP has two settings, ALLOW and PREVENT. ALLOW is the default setting after
you power-on or reset the library. The following table shows how these settings affect
the CAPs. For CAP LED indicator information see
page
35.
CAP Condition
All of the CAPs are closed
Any of the CAPs are open
18 SL500 User's Guide • July 2008
ALLOW
When you press the CAP button
all of the CAPs in the rack will
open.
The library firmware turns on
the CAP LED.
When you press the CAP
button, any CAP that is not
open in the rack will open.
"Controls and Indicators" on
PREVENT
When you press the CAP
button, the action is ignored and
all of the CAPs remain closed.
When you press the CAP
button, the action is ignored and
all of the CAPs remain in their
individual current state of open
or closed.