External REMOTE 2 terminal
Make out the necessary circuit to use this function by referring to the following.
External remote terminal Signal allocation Connector MINI DIN8PIN
Pin No.
Function
1
Ground
2
MEMORY
PHOTO
3
BUSY 2
4
BUSY 1
5
PRINT
6
REMOTE
7
Unused
8
DC3V
• When carrying out MEMORY, PRINT or PHOTO command through this terminal, use TTL level of 74LS series or
mechanical switch.
• Select the function of Pin No. 2 (MEMORY or PHOTO*), with 2. REMOTE SETTING in MEMORY SW MENU.
NORMAL ....... MEMORY function
PRE-CUT ...... PHOTO function
• When the signal from BUSY terminal is received with TTL level, keep the following.
|1
| =2mA or less, |1
OL
|1
| shows the current flowing into the unit at Low output, | 1
OL
output.
8. Printing procedures (Special prints)
Transmission/
Destination
---
Earth
VCP
Memory: When the signal becomes "LOW" from "HIGH", the image is
stored in memory. (When the signal has been "LOW" for 60msec. or
more, the image is stored in memory.)
VCP
When the signal is switched to "HIGH" level* or "Open" status* during
not printing, the setting will be switched to the mode for pre-cut sheet.
(Refer to page 56.)
When the signal is switched to "LOW" level*, "3.ADDITIONAL" in MAIN
MENU is set to the set conditions.
PC
" HIGH " : The VCP cannot accept MEMORY, PRINT and PHOTO signals.
" LOW " : The VCP can accept MEMORY, PRINT and PHOTO signals.
When "BUSY LEVEL" in REMOTE SETTING is set to "LOW", the
setting of "HIGH" and "LOW" becomes inverse. Refer to page 45.
BUSY signal can be defined with BUSY 2.
PC
" HIGH " : The VCP cannot accept MEMORY, PRINT and PHOTO signals.
" LOW " : The VCP can accept MEMORY, PRINT and PHOTO signals.
When "BUSY LEVEL" in REMOTE SETTING is set to "LOW", the
setting of "HIGH" and "LOW" becomes inverse. Refer to page 45.
BUSY signal can be defined with BUSY 1.
VCP
PRINT :When the signal becomes "LOW" from "HIGH", the image
stored in memory is printed. (When the signal has been "LOW" for 60
msec. or more, the image is printed. )
VCP
The same functions as the remote control can be controlled.*
---
---
Power supply for the remote control DC 1mA MAX
* This unit recognizes the signal of 60msec. or more.
• Refer to page 66 for this function.
| =1mA or less
OH
Description
| shows the current flowing out of the unit at High
OH
2
1
4
3
5
6
8
Pin No.
7
65