SETUP LAN PARAMETERS

In this submenu the network parameters are configured. These parameters have to
be adapted to the existing network when the LANTIME is installed the first time. The
following parameters can be set: TCP/IP ADDRESS, NETMASK, DEFAULT
GATEWAY,
Ext.
DOMAINNAME, NAMESERVER, SYSLOG SERVER, SNMP MANAGER,
REMOTE CONNECT, RESET FACTORY SETTINGS und NET LINK
MODE. All settings are applied to the first Ethernet interface only. All further
Ethernet interfaces have to be configured via HTTP or CLI interface. With the
submenu REMOTE CONNECT you can enable or disable all network connections
via TELNET, FTP or HTTP. When the network parameters have been changed the
configuration file is updated and the NTPD is restarted.
With the submenu RESET FACTORY SETTINGS the following parameters will
be set to the default values:
All configuration parameters of the timeserver are saved on the Flash Disk in the file
mnt/flash/global_configuration. It is recommended not to modify this file manually
but to use the configuration interface (HTTP, CLI or SNMP). If this file does not
exist, an empty file is generated. The default configuration file is part of the
attachment.
The parameters for speed and mode of the net card can be changed with the menu
item NET LINK MODE. There are 5 modes available: Autosensing, 10 MBit/Half-
Duplex, 100 MBit/Half-Duplex, 10 MBit/Full-Duplex, 100 MBit/Full-Duplex.
Default setting is Autosensing.

ENABLE OUTPUTS

This menu lets the user configure at which time after power up the serial ports,
pulse outputs, and frequency synthesizer output are to be enabled. Outputs which are
shown to be enabled always will be enabled immediately after power-up. Outputs
which are shown to be enabled if sync will be enabled after the receiver has decoded
the signals from the satellites and has checked or corrected its on-board clock. The
default setting for all outputs is if sync.
Pulses:
NTP
Server,
TCP/IP ADDRESS
000.000.000.000
Reset factory settings
INC -> YES
ENABLE OUTPUTS
if sync
Serial:
28
IPv6
ADDRESS,
MENU -> NO
always
HOSTNAME,