2 Important Safety Information 2.1 Important Safety Information and Safety Precautions The following safety information must be observed whenever the device is being installed or operated. Failure to observe this safety information and other special warnings or operating instructions in the product manuals constitutes improper usage and may violate safety standards and the manufacturer’s requirements.
2 Important Safety Information 2.2 Used Symbols The following symbols and pictograms are used in this manual. Pictograms are used in particular to indicate potential hazards in all hazard categories. Symbol Beschreibung / Description IEC 60417-5031 Gleichstrom / Direct current IEC 60417-5032 Wechselstrom / Alternating current IEC 60417-5017...
2.3 Product Documentation Detailed product documentation is provided on a USB flash drive delivered with the Meinberg system. The manuals can also be downloaded from the Meinberg website at https://www.meinbergglobal.com, where you can enter your system name into the search box at the top of the page to find the relevant manual. Alternatively, contact Meinberg Support for further assistance.
2 Important Safety Information 2.4 Safety during Installation WARNING! Pre-Operation Procedures and Preparation for Use This mountable device has been designed and examined in accordance with the requirements of the standard IEC 62368-1 "Audio/Video, Information and Communication Technology Equipment - Part 1: Safety Requirements". When the mountable device is to be used as part of a larger unit (e.g., electrical enclosure), there will be additional requirements in the IEC 62368-1 standard that must be observed and complied with.
Page 9
= 90 - 250 V Faulty shielding or cabling and improperly connected plugs are a health & safety risk (risk of injury or death due to electrical shock) and may damage or even destroy your Meinberg device or other equipment.
Page 10
2 Important Safety Information AC Power Supply DC Power Supply The device is a Protection Class 1 device and In accordance with IEC 62368-1, it must be • • may only be connected to a grounded outlet possible to disconnect the appliance from the (TN system).
2.5 Connection of Protective Earth Conductor/Grounding ATTENTION! In order to ensure that the device can be operated safely and to meet the requirements of IEC 62368-1, the device must be correctly connected to the protective earth conductor via the protective earth connection terminal. If an external ground connection is provided on the housing, it must be connected to the grounding busbar (earthing busbar) for safety reasons before connecting the power supply.
2 Important Safety Information 2.6 Replacing the Fuse WARNING! This equipment is operated at a hazardous voltage. Danger of death from electrical shock! The device must be disconnected from the mains! This is done using the physical power switch. Once the power switch is OFF, release the lock screws of the power supply connector and detach the connector.
2.7 Safety During Operation WARNING! Avoiding Short-Circuits Protect the device against all ingress of solid objects or liquids. Ingress presents a risk of electric shock or short-circuiting! Ventilation Slots Ensure that ventilation slots are clean and uncovered at all times. Blocked ventilation slots may cause heat to be trapped in the system, resulting in overheating.
(approx. 60 N) presents a risk of injury to the hands. Information on which components are approved for installation can be obtained from Meinberg Technical Support. The device must not be opened. Repairs to the device may only be performed by the manufacturer or authorized personnel.
The battery is used to power components such as the RAM and the reserve real-time backup clock for the reference clock. If the battery voltage drops below 3 V DC, Meinberg recommends having the battery replaced. If the battery voltage drops below the specified minimum, the following behavior may be...
2 Important Safety Information 2.10 Cleaning and Care ATTENTION! Never clean the device using liquids! Water ingress is a significant safety risk for the user (e.g., electric shock). Liquids can cause irreparable damage to the electronics of the device! The ingress of liquids into the device chassis may cause short circuits in the electronic circuitry.
When disposing of your old equipment, please use the national return or collection systems available to you. Alternatively, you may contact Meinberg, who will provide further assistance. The return of electronic waste may not be accepted if the device is soiled or contaminated in such a way that it potentially presents a risk to human health or safety.
External NTP time servers are also possible. The LANTIME M100/GPS system is a set of equipment composed of an integrated time code receiver, a single-board computer and a power supply, all installed in a DIN-railmount chassis and ready to operate. A simplified LINUX operating system is installed on the single-board computer’s flash disk.
Page 21
External Ground Terminal on the Chassis Vor Öffnen des Gerätes alle Stecker ziehen! Before opening disconnect all mains! Avant d´ ´ ouvrir I´ ´ appareil débranchez tous les câbles d´ ´ alimentation This terminal must be wired to a bonding busbar (grounding busbar). The terminal is located on the side of the chassis with the power supply unit.
5 LANTIME M100 Front Connectors 5 LANTIME M100 Front Connectors 100-240 V 50-60 Hz 100-240 V 250V T 1A Antenna Antenna GNSS | IF | 15 V "Ref. Time" green: The reference clock (e.g. build-in GPS) provides a valid time red: The reference clock does not provide a valid time...
5.1 AC/DC - Power Supply Connector Type: 5-Pin MSTB Pin Assignment: 1: N/- 2: not connected 3: PE (Protective Earth) 4: not connected 100-240 V 50-60 Hz 5: L/+ 100-240 V Power Supply Specifications ——————————————————————————– Rated Voltage Range: 100–240 V 100–240 V Max.
5 LANTIME M100 Front Connectors 5.1.1 Option DC-Power Supply Connector: 5pin DFK Pin Assignment: 1: not connected 2: V 3: PE (Protective Earth) 4: V 5: not connected Input Parameter —————————————————————————— Nominal voltage range: = 48 V Maximum voltage range: = 20 - 60 V Nominal current: = 0.63 A...
5.2 Fuse The fuse protects the device from overload and short circuits, and thus prevents damage to the installed power supply. This fuse is accessible from the front panel and can be replaced. Technical Specifications ———————————————————— Rated Voltage: 250 V Trigger Delay: Slow-Blow Rated Current:...
5 LANTIME M100 Front Connectors 5.3 Status LEDs Init Blue: Clock is initializing Green: Oscillator is "warmed up" (disciplined) Fail Signal Antenna Green: Geolocation complete Signal Init Antenna Red: Antenna has a fault, is not correctly connected, or is short-circuited Green: Antenna is connected and clock is synchronized Fail...
5.4 Terminal A serial terminal connection (for certain device mod- els) can be established using the "CONSOLE" RJ45 connector of the LANTIME. The PC can be connected to the time server using a CAB-CONSOLE-RJ45 ca- TXD_OUT ble. This terminal connection can be used to perform 4 + 5 configuration of the time server via the command line RXD_IN...
6 Installation of a GPS Antenna 6 Installation of a GPS Antenna Danger! Do not mount the antenna without an effective fall arrester! Danger of death from falling! • Ensure that you work safely when installing antennas! • Never work without an effective fall arrester! Danger! Do not work on the antenna system during thunderstorms! Danger of death from electric shock!
Page 31
Case Example 4: If the cable leading from the point of entry into the building to the Meinberg system is laid together with other cables (for example in a cable duct alongside high-voltage cables), transient voltages may "leak" into the antenna cable, causing damage to your system.
Page 32
Type-N (Male) If installed in a waterproof housing, the MBG S- Type-N (Female) PRO can be installed outdoors. However, Meinberg recommends installing the surge protector indoors—as closely to the entrance point of the antenna cable as possible—in order to minimize the risk of surge dam- age (such as that caused by lightning strike).
Page 33
Grounding Conductor To ground the antenna cable, connect the surge protec- to Grounding Busbar tor to a grounding busbar using a grounding conductor Conductor of diameter approx. 1.5 mm (see illustration). attached to surge protector As short as possible Once installation is complete, connect the other end of the antenna cable to the surge protector female con- nector.
Page 34
The splitter may be installed at any location between the surge protector and the receivers. Information: Please note for installation purposes that GNSS L1 components cannot be directly connected to or used with a Meinberg GPS antenna distributor. Antenna Receiver Antenna Splitter...
7.1 Technical Specifications: Antenna Cable The table below shows which coaxial cable types and lengths are supported by Meinberg for each of the receiver types. If you need to purchase a replacement cable at any time, please refer to this table to ensure that you select cable with suitable cutoff...
7 Technical Appendix: GPS Antenna + Accessories 7.3 Technical Specifications: MBG S-PRO Surge Protector Adapter plug with replaceable gas discharge tube for coaxial signal connections. Connector Type: Type-N connector female/female. The MBG S-PRO set includes a surge protector (Phoenix CN-UB-280DC-BB), a pre-assembled coaxial cable, and a mounting bracket. The coaxial cable surge protector must be installed on the antenna line.
Page 39
Max. Discharge Current: (8/20) s Maximum (Core-Shield) 20 kA Rated Pulse Current: (10/1000) s (Core-Shield) 100 A Impulse Discharge Current: (10/350) s, Peak Value I 2.5 kA Output Voltage Limit: At 1 kV/ s (Core-Earth) spike 900 V At 1 kV/ s (Core-Earth) spike 900 V Response Time: tA (Core-Earth)
WEEE-compliant fashion, it can be returned to the manufacturer. Any transportation ex- penses for returning this product (at end-of-life) must be covered by the end user, while Meinberg will bear the costs for the waste disposal itself. Date: October 26, 2022...
9 Declaration of Conformity 9 Declaration of Conformity Declaration of Conformity Doc ID: LANTIME M100/GPS-October 25, 2022 Hersteller Meinberg Funkuhren GmbH & Co. KG Manufacturer Lange Wand 9, D-31812 Bad Pyrmont erklärt in alleiniger Verantwortung, dass das Produkt, declares under its sole responsibility, that the product...