Time Strings; Format Of The Meinberg Standard Time String - Meinberg LANTIME/GPS Operating Instructions Manual

Etx 1he
Table of Contents

Advertisement

Time Strings

Format of the Meinberg Standard Time String

The Meinberg Standard Time String is a sequence of 32 ASCII characters starting
with the STX (start-of-text) character and ending with the ETX (end-of-text)
character. The format is:
The letters printed in italics are replaced by ASCII numbers whereas the other
characters are part of the time string. The groups of characters as defined below:
<STX>
Start-Of-Text (ASCII code 02h)
sending with one bit occuracy at change of second
dd.mm.yy
the current date:
hh.mm.ss
the current time:
uv
clock status characters:
x
time zone indicator:
y
announcement of discontinuity of time, enabled during last hour before
discontinuity comes in effect:
<ETX>
End-Of-Text (ASCII code 03h)
<STX>D:dd.mm.yy;T:w;U:hh.mm.ss;uvxy<ETX>
dd
day of month
mm
month
yy
year of the century
w
the day of the week
hh
hours
mm
minutes
ss
seconds
u:
'#' clock has not synchronized after reset
' ' (space, 20h) clock has synchronized after reset
v:
different for DCF77 or GPS receivers:
'*' DCF77 clock currently runs on XTAL
GPS receiver has not checked its position
' ' (space, 20h) DCF77 clock is sync'd with transmitter
GPS receiver has determined its position
'U'
UTC
Universal Time Coordinated, formerly GMT
' '
MEZ
European Standard Time, daylight saving disabled
'S'
MESZ
European Summertime, daylight saving enabled
'!'
announcement of start or end of daylight saving time
'A'
announcement of leap second insertion
' '
(space, 20h) nothing announced
(01..31)
(01..12)
(00..99)
(1..7, 1 = Monday)
(00..23)
(00..59)
(00..59, or 60 while leap second)
123

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents