Assignment Of Cf Segment In Ieee1344 Code - Meinberg LANTIME/GPS Operating Instructions Manual

Etx 1he
Table of Contents

Advertisement

Assignment of CF Segment in IEEE1344 Code

Bit No.
Designation
49
Position Identifier P5
50
Year BCD encoded 1
51
Year BCD encoded 2
52
Year BCD encoded 4
53
Year BCD encoded 8
54
empty, always zero
55
Year BCD encoded 10
56
Year BCD encoded 20
57
Year BCD encoded 40
58
Year BCD encoded 80
59
Position Identifier P6
60
LSP - Leap Second Pending
61
LS - Leap Second
62
DSP - Daylight Saving Pending
63
DST - Daylight Saving Time
64
Timezone Offset Sign
65
TZ Offset binary encoded 1
66
TZ Offset binary encoded 2
67
TZ Offset binary encoded 4
68
TZ Offset binary encoded 8
69
Position Identifier P7
70
TZ Offset 0.5 hour
71
TFOM Time figure of merit
72
TFOM Time figure of merit
73
TFOM Time figure of merit
74
TFOM Time figure of merit
75
PARITY
current firmware does not support leap deletion of leap seconds
1.)
TFOM is cleared, when clock is synchronized first after power up. see chapter Selection of generated timecode
2.)
Description
low nibble of BCD encoded year
high nibble of BCD encoded year
set up to 59s before LS insertion
0 = add leap second, 1 = delete leap second
set up to 59s before daylight saving changeover
set during daylight saving time
sign of TZ offset 0 = '+', 1 = '-'
Offset from IRIG time to UTC time.
Encoded IRIG time plus TZ Offset equals UTC
at all times !
set if additional half hour offset
time figure of merit represents approximated
clock error.
2.)
0x00 = clock locked
0x0F = clock failed
parity on all preceding bits incl. IRIG-B time
117
1.)

Hide quick links:

Advertisement

Table of Contents
loading