Meinberg LANTIME M300 Technical Reference

Meinberg LANTIME M300 Technical Reference

Hide thumbs Also See for LANTIME M300:

Advertisement

Quick Links

TECHNICAL REFERENCE
LANTIME
M300/GNS/LNE/AD10-AD10
October 27, 2022
Meinberg Funkuhren GmbH & Co. KG

Advertisement

Table of Contents
loading

Summary of Contents for Meinberg LANTIME M300

  • Page 1 TECHNICAL REFERENCE LANTIME M300/GNS/LNE/AD10-AD10 October 27, 2022 Meinberg Funkuhren GmbH & Co. KG...
  • Page 3: Table Of Contents

    3 General Information about LANTIME 4 LANTIME Chassis: Technical Specifications 5 LANTIME M300 Front Connectors 6 LANTIME M300 Rear Connectors AC/DC Power Supply ..........
  • Page 4: Imprint

    1 Imprint 1 Imprint Meinberg Funkuhren GmbH & Co. KG Lange Wand 9, 31812 Bad Pyrmont, Germany Phone: + 49 (0) 52 81 / 93 09 - 0 Fax: + 49 (0) 52 81 / 93 09 - 230 Website: https://www.meinbergglobal.com Email: info@meinberg.de...
  • Page 5: Important Safety Information

    2 Important Safety Information 2.1 Important Safety Information and Safety Precautions The following safety information must be observed whenever the device is being installed or operated. Failure to observe this safety information and other special warnings or operating instructions in the product manuals constitutes improper usage and may violate safety standards and the manufacturer’s requirements.
  • Page 6: Used Symbols

    2 Important Safety Information 2.2 Used Symbols The following symbols and pictograms are used in this manual. Pictograms are used in particular to indicate potential hazards in all hazard categories. Symbol Beschreibung / Description IEC 60417-5031 Gleichstrom / Direct current IEC 60417-5032 Wechselstrom / Alternating current IEC 60417-5017...
  • Page 7: Product Documentation

    2.3 Product Documentation Detailed product documentation is provided on a USB flash drive delivered with the Meinberg system. The manuals can also be downloaded from the Meinberg website at https://www.meinbergglobal.com, where you can enter your system name into the search box at the top of the page to find the relevant manual. Alternatively, contact Meinberg Support for further assistance.
  • Page 8: Safety During Installation

    2 Important Safety Information 2.4 Safety during Installation WARNING! Pre-Operation Procedures and Preparation for Use This mountable device has been designed and examined in accordance with the requirements of the standard IEC 62368-1 "Audio/Video, Information and Communication Technology Equipment - Part 1: Safety Requirements". When the mountable device is to be used as part of a larger unit (e.g., electrical enclosure), there will be additional requirements in the IEC 62368-1 standard that must be observed and complied with.
  • Page 9 = 90 - 250 V Faulty shielding or cabling and improperly connected plugs are a health & safety risk (risk of injury or death due to electrical shock) and may damage or even destroy your Meinberg device or other equipment.
  • Page 10 2 Important Safety Information AC Power Supply DC Power Supply The device is a Protection Class 1 device and In accordance with IEC 62368-1, it must be • • may only be connected to a grounded outlet possible to disconnect the appliance from the (TN system).
  • Page 11: Connection Of Protective Earth Conductor/Grounding

    2.5 Connection of Protective Earth Conductor/Grounding ATTENTION! In order to ensure that the device can be operated safely and to meet the requirements of IEC 62368-1, the device must be correctly connected to the protective earth conductor via the protective earth connection terminal. If an external ground connection is provided on the housing, it must be connected to the grounding busbar (earthing busbar) for safety reasons before connecting the power supply.
  • Page 12: Safety During Operation

    2 Important Safety Information 2.6 Safety During Operation WARNING! Avoiding Short-Circuits Protect the device against all ingress of solid objects or liquids. Ingress presents a risk of electric shock or short-circuiting! Ventilation Slots Ensure that ventilation slots are clean and uncovered at all times. Blocked ventilation slots may cause heat to be trapped in the system, resulting in overheating.
  • Page 13: Safety During Maintenance

    Opening the device or individual device components in an unauthorized fashion may also expose the user to considerable risks and invalidate your warranty. Meinberg Funkuhren accepts no liability for consequences arising from such unauthorized actions. Danger from moving parts—do not touch moving parts.
  • Page 14: Handling Of Batteries

    The battery is used to power components such as the RAM and the reserve real-time backup clock for the reference clock. If the battery voltage drops below 3 V DC, Meinberg recommends having the battery replaced. If the battery voltage drops below the specified minimum, the following behavior may be...
  • Page 15: Cleaning And Care

    2.9 Cleaning and Care ATTENTION! Never clean the device using liquids! Water ingress is a significant safety risk for the user (e.g., electric shock). Liquids can cause irreparable damage to the electronics of the device! The ingress of liquids into the device chassis may cause short circuits in the electronic circuitry. Only clean with a soft, dry cloth.
  • Page 16: Return Of Electrical And Electronic Equipment

    When disposing of your old equipment, please use the national return or collection systems available to you. Alternatively, you may contact Meinberg, who will provide further assistance. The return of electronic waste may not be accepted if the device is soiled or contaminated in such a way that it potentially presents a risk to human health or safety.
  • Page 17: General Information About Lantime

    3 General Information about LANTIME LANTIME stands for Local Area Network Time Server. The LANTIME provides an absolute and highly precise time reference in a TCP/IP network (stratum 1 server). The time is made available to all NTP clients via the NTP protocol (Network Time Protocol) and allows easy integration of an absolute time reference into an existing network.
  • Page 18: Lantime Chassis: Technical Specifications

    4 LANTIME Chassis: Technical Specifications 4 LANTIME Chassis: Technical Specifications Chassis: 19" Multipac Chassis, 1U Chassis Material: Sheet Steel ——————————————————————————- Temperature Range Operation: 0–50 C (32–122 F) Storage: -20–70 C (-4–158 F) ——————————————————————————- Relative Humidity Operation: Max. 93 % (Non-Condensing) at 40 C ——————————————————————————- Maximum Altitude Operation:...
  • Page 19 Chassis Dimensions 483 mm 19 inch 465 mm 18.31 inch 43,6 mm 1.72 inch 31,8 mm 1.25 inch 445 mm 17.51 inch 288 mm 11.32 inch 304 mm 11.98 inch External Ground Terminal on the Chassis This terminal must be wired to a bonding busbar (grounding busbar). The terminal is located on the side of the chassis with the power supply unit.
  • Page 20: Lantime M300 Front Connectors

    5 LANTIME M300 Front Connectors 5 LANTIME M300 Front Connectors The main menu is displayed after the device is switched on and the boot phase is completed. The main menu provides the most important status infor- mation. The top line of the display shows the operating mode of the reference clock / reference time and will normally read "GNS: NORMAL OPERATION", al-...
  • Page 21 "Ref. Time" Green: A valid time is provided by the reference clock (e.g., integrated GNS) Red: There is no valid time available from the reference clock "Time Service" Green: NTP is synchronized with the reference clock (e.g., GNS) Red: NTP is not synchronized or has switched to the "local clock"...
  • Page 22: Lantime M300 Rear Connectors

    6 LANTIME M300 Rear Connectors 6 LANTIME M300 Rear Connectors 6.1 AC/DC Power Supply Information: Hot-Plugging Support Only if the LANTIME is operated with a redundant power supply can either one of the power supply units be removed or installed from the system chassis while the device is in operation (for example, due to a fault in the PSU).
  • Page 23 Required Tools • Slotted Screwdriver: 0.4 mm Tip Thickness, 2.5 mm Tip Width • Torx Screwdriver: TR8x60 Instructions for Hot-Pluggable Power Supplies Replacing the Power Supply Unit Cut off the power supply to the module by pulling the mains plug of the power supply cable out of the mains socket.
  • Page 24 6 LANTIME M300 Rear Connectors Connector Type: 5-Pin MSTB Pin Assignment: 1: N/- 2: Not Connected AD10 3: PE (Protective Earth) 4: Not Connected Power 5: L/+ Power Supply Specifications = 100 V - 240 V = 90 V - 265 V ——————————————————————————...
  • Page 25: Comx Time String: Rs-232

    6.2 COMx Time String: RS-232 Data Transfer: Serial Baud Rate/Framing: 19200 / 8N1 (Default) Time String: Meinberg Standard (Default) Assignment: Pin 2: TxD (Transmit) Pin 3: RxD (Receive) Pin 5: GND (Ground) COM x Connection Type: D-Sub Female 9-Pin Cable:...
  • Page 26: Error Relay

    6 LANTIME M300 Rear Connectors 6.3 Error Relay The device is equipped with a 3-pin relay output la- beled with "Error". This 0 V ("dry") relay output is connected to the TTL TIME_SYNC output of the refer- Error ence clock (GPS, PZF, TCR, etc.) Normally, when the...
  • Page 27: Antenna Input: Gnss Reference Clock

    6.4 Antenna Input: GNSS Reference Clock Antenna Type: Multi GNSS L1 Antenna with Integrated Lightning Protection Receiver Type: 72-Channel Receiver GPS/GLONASS/Galileo/BeiDou Signal Support: GPS: L1 C/A (1575.42 MHz) Galileo: E1-B/C (1575.42 MHz) BeiDou: B1I (1561.098 MHz) GLONASS: L1OF (1602 MHz + k*562.5 kHz) where k represents the channel number (in the range -7 to 6) within the...
  • Page 28: Pulse Per Second Output

    6 LANTIME M300 Rear Connectors 6.5 Pulse per Second Output Output Signal: PPS (Pulse per Second) Signal Level: TTL 2.5 V, 50 Termination Pulse Length: 200 ms Connector Type: BNC Female PPS Out Cable: Coaxial Cable, Shielded 6.6 10 MHz Frequency Output...
  • Page 29: Gnss Antenna Installation

    7 GNSS Antenna Installation Two different antennas are available for our combined GPS/GLONASS/Galileo/BeiDou satellite receivers that are each designed to fulfill different tasks or applications. The active Multi-GNSS L1 antenna is the standard accessory and can receive signals from the GPS, GLONASS, Galileo, and BeiDou satellite systems.
  • Page 30: Installation Of The Multi-Gnss Antenna

    7 GNSS Antenna Installation 7.1 Installation of the Multi-GNSS Antenna Danger! Do not mount the antenna without an effective fall arrester! Danger of death from falling! • Ensure that all necessary safety measures are taken when installing an antenna! • In particular, never work without an effective fall arrester! Danger! Do not work on the antenna system during thunderstorms! Danger of death from electric shock!
  • Page 31 Case Example 4: If the cable leading from the point of entry into the building to the Meinberg system is laid together with other cables (for example in a cable duct alongside high-voltage cables), transient voltages may "leak" into the antenna cable, causing damage to your system.
  • Page 32 Type-N (Male) If installed in a waterproof housing, the MBG S- Type-N (Female) PRO can be installed outdoors. However, Meinberg recommends installing the surge protector indoors—as closely to the entrance point of the antenna cable as possible—in order to minimize the risk of surge dam- age (such as that caused by lightning strike).
  • Page 33 Grounding Conductor To ground the antenna cable, connect the surge protec- to Grounding Busbar tor to a grounding busbar using a grounding conductor Conductor of diameter approx. 1.5 mm (see illustration). attached to surge protector As short as possible Once installation is complete, connect the other end of the antenna cable to the surge protector female con- nector.
  • Page 34 The splitter may be installed at any location between the surge protector and the receivers. Information: It is not possible to directly connect a Meinberg GPS antenna/converter unit to an L1 antenna splitter. Antenna Receiver...
  • Page 35: Assembly Of The Rv-76G Gps/Glonass Antenna For Mobile Applications

    7.2 Assembly of the RV-76G GPS/GLONASS Antenna for Mobile Applications Installation of the Antenna Further Information on the Product Detailed specifications are provided in the manufacturer’s data sheet. Source: Datasheet RV-76G_Catalog_V1.0_20130502 (Sanav) https://www.meinbergglobal.com/download/docs/other/rv-76g_en.pdf Download: Date: October 27, 2022 LANTIME...
  • Page 36: Information On Satellite Reception

    Your system is fitted with the GNS, a 72-channel satellite receiver clock which serves as a high-accuracy time reference and high-precision frequency reference for your Meinberg system and is designed to receive signals from the United States GPS (Global Positioning System), Russian GLONASS (GLObal NAvigation Satellite System), the European Galileo system, and the Chinese BeiDou system.
  • Page 37: Time Zones And Daylight Saving Time

    8.2.1 Time Zones and Daylight Saving Time GPS System Time is a linear timescale that was synchronized with the international UTC timescale (Coor- dinated Universal Time) when the satellite system became operational in 1980. Since it has entered service, however, several leap seconds have been introduced to the UTC timescale to adjust UTC time to irregularities in the Earth’s rotation.
  • Page 38: Rohs And Weee

    WEEE-compliant fashion, it can be returned to the manufacturer. Any transportation ex- penses for returning this product (at end-of-life) must be covered by the end user, while Meinberg will bear the costs for the waste disposal itself. LANTIME...
  • Page 39: Declaration Of Conformity

    10 Declaration of Conformity Declaration of Conformity Doc ID: LANTIME M300/GNS/LNE/AD10-AD10-June 17, 2021 Hersteller Meinberg Funkuhren GmbH & Co. KG Manufacturer Lange Wand 9, D-31812 Bad Pyrmont erklärt in alleiniger Verantwortung, dass das Produkt, declares under its sole responsibility, that the product...

This manual is also suitable for:

Lantime gnsLantime lneLantime ad10-ad10

Table of Contents