Setup Serial Port; Setup Serial String Type - Meinberg LANTIME/GPS Operating Instructions Manual

Etx 1he
Table of Contents

Advertisement

SETUP SERIAL PORT

This menu lets the user configure the baud rate and the framing of the serial RS232
port to one of the following values:
COM provides a time string once per second, once per minute or on request. If the
„on request" is activated you have to send the charakter „?" to get the timestring.
PARM: 19200 8N1

SETUP SERIAL STRING TYPE

This topic is used to select one of several different types of serial time strings or the
capture string for each serial port.
The following time strings can be selected. All time strings are described in the
appendix at the end of this documentation.
-
Meinberg Standard String
-
GPS167 Capture String
-
SAT String
-
UNI-Erlangen String
-
NMEA String (RMC)
-
SPA String
-
Computime String
Refer to chapter Time Strings for details.
Baud Rate:
300 to 19200
Framing:
7E2, 8N1, 8E1, 8O1
Default:
COM: 19200 baud, 8N1, once per second
SERIAL PORT
STRING TYPE
STRING TYPE:
MODE: PER SECOND
Meinberg Standard
31