Test Messages; Sense Codes; A.2.5 Test Messages; A.2.6 Sense Codes - Fujitsu Eternus DX80 S2 User Manual

Disk storage system
Hide thumbs Also See for Eternus DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
A.2.5

Test Messages

The messages that are sent when the test notification of an event is performed in ETERNUS
Web GUI or ETERNUS CLI are described below.
Test mail transmission
The message is notified when the test notification of e-mail is performed in ETERNUS Web GUI
or ETERNUS CLI.
Event type code
T FFFFFFFF
Test Trap transmission
The message is notified when the test notification of the SNMP Trap is performed in ETERNUS
Web GUI or ETERNUS CLI.
Trap No.
2
A.2.6

Sense Codes

This section describes the sense codes that are notified to the server.
Sense code
SK
02
04
04
04
04
04
04
04
04
04
04
04
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
Test e-mail Message
TrapItemId
0x80000000
SNMP Trap Test
The Trap No. and ItemId in the test Trap are the same as the notification
that is sent when a drive in Slot#0 in CE is in Fault status. A drive is not
actually disconnected when a test Trap is notified.
ASC
ASCQ
04
00
The device is in Not Ready status.
F1
01
CM is disconnected.
F1
0B
CM memory is disconnected.
F1
0C
CM BUD is disconnected.
F1
0D
CM FAN is disconnected.
F1
10
CA is disconnected.
F1
11
CA Port is disconnected.
F1
1A
CA SFP is disconnected.
F1
1C
CA SFP+ is disconnected.
F1
1D
CA SFP+ is disconnected.
F1
1F
CA SFP is disconnected due to an SFP type that
cannot be recognized.
F1
2A
CM QSFP is disconnected.
Copyright 2012 FUJITSU LIMITED
Message
TrapMessage
Description
138
Remarks
This sense code is notified when "Not
ready" is enabled for Error Severity
Level in the event notification setting.
This is not notified during mainte-
nance operations.
These sense codes are notified when
"Parts Error" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during mainte-
nance operations.
P3AM-4842-03ENZ0