Figure 1.7 2.5" Drive - Fujitsu Eternus DX80 S2 User Manual

Disk storage system
Hide thumbs Also See for Eternus DX80 S2:
Table of Contents

Advertisement

Chapter 1 Components
1.1 Controller Enclosure
Part explanation
Power switch
This switch is used to turn on or off the ETERNUS DX Disk storage system.
FUNCTION button
Hold down the button for three seconds during maintenance to stop the maintenance
operation. Hold down the button for three seconds while a maintenance operation is not
performed to start the maintenance operation.
For a dual-controller type, press the button twice within three seconds during maintenance to
switch the Master CM to the other controller.
Press the button three times within three seconds during maintenance to restore the factory
default settings of the LAN ports.
LEDs
The states of LEDs are listed below.
Table 1.1
POWER
READY
FAULT
MAINT/ID
CACHE
Drives
2.5" drives
DRIVE READY LED
Figure 1.7
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
Status and meanings of each LED (operation panel (controller enclosure))
LED name
LED status
(green)
(green)
(orange)
(blinks orange)
(green)
(blinks green)
(green)
DRIVE FAULT LED
2.5" drive
Copyright 2012 FUJITSU LIMITED
ETERNUS DX Disk storage system status
DC power is supplied to the controller enclosure.
The ETERNUS DX Disk storage system is available
for use.
The ETERNUS DX Disk storage system is in error
status.
A part of the ETERNUS DX Disk storage system
requires preventive maintenance.
Maintenance for the ETERNUS DX Disk storage
system is in progress.
As ordered via ETERNUS Web GUI or ETERNUS
CLI, the location of the controller enclosure is
identified.
Maintenance or a status check via ETERNUS Web
GUI or ETERNUS CLI is necessary.
There is data in the ETERNUS DX Disk storage
system cache memory.
16
P3AM-4842-03ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents