Appendix A Event Notification Message List
A.2 Message List
Event type
code
J 0ASSMMvp
J 0CSSMM0v
J 0ESSMM00
J 0FSSMM00
J 10SSMM00
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
(*1)
No.
5
0A00MMvp
0
5
0C00MM0v
0
5
0E00MM00
0
5
0F00MM00
0
5
1000MM00
0
125
Copyright 2012 FUJITSU LIMITED
Upper: Message
Lower: Description
Controller Module#m(zz) EXP#v Out Port#p
Warning <pppppppppppp ssssssssss rrrrr>
CM EXP OUT port error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: EXP number (0)
p: Port number (0)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) BUD#v(#xxGB)
Warning <pppppppppppp ssssssssss rrrrr>
CM BUD error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: BUD number (0 – 1)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
xx: Capacity of BUD (2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) NAND Controller
Warning <pppppppppppp ssssssssss rrrrr>
CM NAND Controller error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) SCU Warning
<pppppppppppp ssssssssss rrrrr>
CM SCU error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
CA Slot#S-V(zz) (on CM#m) Warning
<pppppppppppp ssssssssss rrrrr>
CA error is detected.
SS: Component subtype
MM: CA module ID (40 – 7F)
S: CA slot number (0 – 1)
V: Device number (0 – 1)
zz: CA type
m: CM number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
Remarks
These mes-
sages are noti-
fied when
"Parts Warn-
ing" is enabled
for Warning
Level in the
event notifica-
tion setting.
They are not
notified during
maintenance
operations.
P3AM-4842-03ENZ0

Hide quick links:

Advertisement