Warning Messages; A.2.3 Warning Messages - Fujitsu Eternus DX80 S2 User Manual

Disk storage system
Hide thumbs Also See for Eternus DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
A.2.3

Warning Messages

This section describes the messages that are sent when the severity is Warning.
Warning message list
The following messages are sent when components require maintenance or preventive mainte-
nance, when the battery reaches its expiration date, for unusual temperatures, and for other
warning events.
Event type
code
J 01SSMM00
J 02SSMM0p
J 03SSMM0v
J 04SSMM00
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
(*1)
No.
5
0100MM00
0xww
5
0200MM0p
0
5
0300MM0v
0
5
0400MM00
0
123
Copyright 2012 FUJITSU LIMITED
Upper: Message
Lower: Description
Controller Module#m(zz) Warning factor(ww)
<pppppppppppp ssssssssss rrrrr>
CM error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
ww: Factor code
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) DMA PORT#p
Warning <pppppppppppp ssssssssss rrrrr>
CM DMA port error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
p: Port number (0)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) BIOS#v Warning
<pppppppppppp ssssssssss rrrrr>
CM BIOS error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: BIOS number (0 – 1)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) RTC Warning
<pppppppppppp ssssssssss rrrrr>
CM RTC error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Remarks
These mes-
sages are noti-
fied when
"Parts Warn-
ing" is enabled
for Warning
Level in the
event notifica-
tion setting.
They are not
notified during
maintenance
operations.
P3AM-4842-03ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents