Appendix A Event Notification Message List
A.2 Message List
A.2.3
Warning Messages
This section describes the messages that are sent when the severity is Warning.
■
Warning message list
The following messages are sent when components require maintenance or preventive mainte-
nance, when the battery reaches its expiration date, for unusual temperatures, and for other
warning events.
Event type
code
J 01SSMM00
J 02SSMM0p
J 03SSMM0v
J 04SSMM00
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
(*1)
No.
5
0100MM00
0xww
5
0200MM0p
0
5
0300MM0v
0
5
0400MM00
0
123
Copyright 2012 FUJITSU LIMITED
Upper: Message
Lower: Description
Controller Module#m(zz) Warning factor(ww)
<pppppppppppp ssssssssss rrrrr>
CM error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
ww: Factor code
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) DMA PORT#p
Warning <pppppppppppp ssssssssss rrrrr>
CM DMA port error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
p: Port number (0)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) BIOS#v Warning
<pppppppppppp ssssssssss rrrrr>
CM BIOS error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: BIOS number (0 – 1)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz) RTC Warning
<pppppppppppp ssssssssss rrrrr>
CM RTC error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
Remarks
These mes-
sages are noti-
fied when
"Parts Warn-
ing" is enabled
for Warning
Level in the
event notifica-
tion setting.
They are not
notified during
maintenance
operations.
P3AM-4842-03ENZ0