Fujitsu Eternus DX80 S2 User Manual page 111

Disk storage system
Hide thumbs Also See for Eternus DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Event type
P 2ASSMMvp 2
P 80SSuu0N
P 80SSuu0N
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
code
TrapItemID
No.
2A00MMvp
2
8000uu0N
2
8000uu0N
Copyright 2012 FUJITSU LIMITED
Upper: Message
Trap
Sensor
Lower: Description
Info
-
Controller Module#m(zz) QSFP#P Fault
<pppppppppppp ssssssssssss rrrr>
CM QSFP is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
v: Device number (0)
p: Device port number (0 – 1)
P: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
-
HDD 3.5 DE#uu-Disk#n(SAS xxxGB yykrpm
ccccccc) Fault <pppppppppppp ssssssssssss
rrrr tttttt qq>
HDD is disconnected.
SS: Component subtype
uu: DE-ID ("00" for a controller enclosure)
N: Disk slot number (0 – b (hexadecimal))
n: Disk slot number (0 – 11 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot
spare (Spare))
pp...: Component number
ss...: Serial number
rr...: Version
tt...: Data code
qq: Configuration code
-
HDD 3.5 DE#uu-Disk#n(SAS xxxGB yykrpm
ccccccc) Failed Usable <pppppppppppp
ssssssssssss rrrr tttttt qq>
HDD is disconnected.
SS: Component subtype
uu: DE-ID ("00" for a controller enclosure)
N: Disk slot number (0 – b (hexadecimal))
n: Disk slot number (0 – 11 (decimal))
xxx: Disk capacity (GB/TB)
yy: Disk speed
cc...: Disk information (RAID level or hot
spare (Spare))
pp...: Component number
ss...: Serial number
rr...: Version
tt...: Data code
qq: Configuration code
111
Remarks
These messages
are notified when
"Parts Error" is
enabled for Error
Severity Level in
the event notifica-
tion setting. They
are not notified
during mainte-
nance operations.
These messages
are notified when
"Disk Error" is
enabled for Error
Severity Level in
the event notifica-
tion setting. They
are not notified
during mainte-
nance operations.
P3AM-4842-03ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents