Warning Messages; A.2.3 Warning Messages - Fujitsu ETERNUS DX60 S2 User Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX60 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Event type
and event
M E2070015
M E2070016
A.2.3

Warning Messages

This section describes the messages that are sent when the severity is Warning.
Warning message list
The following messages are sent when components require maintenance or preventive mainte-
nance, when the battery reaches its expiration date, for unusual temperatures, and for other
warning events.
Event type
and event
code
J 01SSMM00 5
J 06SSMM00 5
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
Trap
Maintenance
code
No.
Info
7
E2070015
NOT READY(21:Configuration Data restored from
System Disk)
Maintenance is performed for the CM in cold mode.
The ETERNUS DX Disk storage system normally powers
off and then on, and the status becomes Ready.
7
E2070016
NOT READY(22:No Version)
The device is in Not Ready status.
The version table is invalid.
SNMP Trap
Trap
TrapItemID
(*1)
No.
0100MM00 0xww
0600MM00 0x00
Copyright 2014 FUJITSU LIMITED
Upper: Message
Lower: Description
Upper: Message
Lower: Description
Controller Module#m(zz xxHz) Warning factor(ww)
<pppppppppppp ssssssssss rrrrr>
CM error other than above is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
ww: Factor code
pp...: Component number
ss...: Serial number
rr...: Version
Controller Module#m(zz xxHz) BE Expander
Warning <pppppppppppp ssssssssss rrrrr>
CM BE Expander error is detected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
104
Remarks
These messages
are notified when
the relevant event
occurs.
Remarks
These messages
are notified when
"Module reported a
Warning" is enabled
for Warning Severity
Level in Setup
Event Notification.
They are not notified
during maintenance
operations.
P3AM-5512-07ENZ0