Snmpcli Examples; Port Configuration Utility - Extreme Networks EPICenter Software Installation Manual

Hide thumbs Also See for EPICenter:
Table of Contents

Advertisement

Table 15: SnmpCli command options (continued)
Option
-r
-t

SNMPCLI Examples

The following examples illustrate the usage of these commands.
• To retrieve the values of the
extremeRedundantPowerStatus
99, with read community string "purple" and a timeout of 1000 ms, enter the following command:
snmpcli snmpget -a 10.205.0.99 -r purple -t 1000 -o .1.3.6.1.4.1.1916.1.1.1.10.0
-o .1.3.6.1.4.1.1916.1.1.1.11.0
This returns the following:
IP Address: 10.205.0.99
Read community string: purple
Timeout(ms): 1000
OUTPUT:
OID: .1.3.6.1.4.1.1916.1.1.1.10.0 ;
OID: .1.3.6.1.4.1.1916.1.1.1.11.0 ;
• To retrieve the values from the
with IP address 10.205.0.99, with the default read community string (public) and a default timeout,
enter the following command:
snmpcli snmpwalk -a 10.205.0.99 -o .1.3.6.1.4.1.1916.1.1.1.9
This returns the following:
IP Address: 10.205.0.99
Read community string: public
Timeout(ms): 500
OUTPUT:
OID: .1.3.6.1.4.1.1916.1.1.1.9.1.1.1 ;
OID: .1.3.6.1.4.1.1916.1.1.1.9.1.1.2 ;
OID: .1.3.6.1.4.1.1916.1.1.1.9.1.1.3 ;
OID: .1.3.6.1.4.1.1916.1.1.1.9.1.2.1 ;
OID: .1.3.6.1.4.1.1916.1.1.1.9.1.2.2 ;
OID: .1.3.6.1.4.1.1916.1.1.1.9.1.2.3 ;

Port Configuration Utility

The Port Configuration utility is a stand-alone utility that runs on the Windows 2000, or Windows XP
platform.
The EPICenter Port Configuration utility provides a way for an EPICenter administrator to change some
of EPICenter's logical TCP/IP port numbers, in the event that there are conflicts between these port
numbers and those used by other software products running on the same system. Because these port
conflicts may prevent EPICenter from running, the port configuration capability needs to be accessible
outside of EPICenter. The Port Configuration application runs on the same system as the EPICenter
Database Server and Web Server.
EPICenter Software Installation and User Guide
Value
Read community string
Timeout value for SNMP request, in milliseconds.
extremePrimaryPowerOperational
variables for the Extreme Networks device with IP address 10.205.0
extremeFanStatusTable
and
VALUE: 1
VALUE: 1
variables for the Extreme Networks device
VALUE: 1
VALUE: 2
VALUE: 3
VALUE: 2
VALUE: 2
VALUE: 2
Port Configuration Utility
Default
public
500 ms
477

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EPICenter and is the answer not in the manual?

This manual is also suitable for:

Epicenter 4.1

Table of Contents