Emerson E2 Installation And Operation Manual page 242

For rx refrigeration, bx hvac, and cx convenience store controllers
Hide thumbs Also See for E2:
Table of Contents

Advertisement

E2 Advisory Text
(Advisory Log)
No 3 Phase Power
Contact Coil Opn Circuit
Current Overload Trip
Phase Loss Trip
Welded Contactor
Suction Pressure Trip
Locked Rotor Trip
Motor Temperature Trip
Protector Trip
Discharge Pressure Trip
Rack Control Lockout
Part Wind Lockout
Low Oil Pressure Lockout
Discharge Pressure Lockout 20
Discharge Temp Lockout
Contact Coil Opn Cir Lock
Locked Rotor Lockout
Part Wind Phase Lockout
Compressor Module Failure 20
Running DLT Fault
Running Injector Open
Running Injector Short
DLT Fault
DLT Fault/Injector Open
DLT Fault/Injector Short
Comp Low Voltage Lockout 20
C-16
E2 RX/BX/CX I&O Manual
E2
Advisory
E2 Display Code Text
Priority
(default)
20
No 3Phase Power
User
Con Coil Open Circuit
20
Current OvrLoad Trip
20
Phase Loss Trip
20
Welded Contactor Warn
User
Low Sct Prs Cutout
20
Locked Rotor Trip
20
Motor Temp Trip
20
Protector Trip
20
High Disch Prs Trip
20
Controller Lockout
20
Part Winding Lockout
20
Low Oil Prs Lockout
High Disch Prs Lock
20
Disch Temp Lockout
20
Con Coil Open Lockout
20
Locked Rotor Lockout
20
Phase Loss Lockout
Comp Module Failure
99
Normal - DLT Fault
99
Inject Fault Open
99
Inject Fault Short
20
DLT Fault
20
DLT Fault Inject Open
20
DLT Fault Inject Shrt
Comp Low Volt Lockout CMP LOWVLT LOCK
E2 Associated Alarm
Property
NO 3PHASE PWR
CON COIL OP WRN
CURRNT OVR TRIP
PHASE LOSS TRIP
WELD CNTCT WARN
SUCT PRT TRIP
LCKD ROTOR TRIP
MOT TEMP TRIP
PROTECTOR TRIP
DISCH PRS TRIP
RACK CNTRL LOCK
PART WIND LOCK
LOW OIL LOCK
DISCH PRES LOCK
DISCH TEMP LOCK
CON COIL OP LCK
LOCK ROTOR LOCK
PART PHASE LOCK
COMP MOD FAIL
RUN DLT FAULT
RUN INJ FLT OPN
RUN INJ FLT SHR
DLT FAULT
DLT FLT INJ OPN
DLT FLT INJ SHR
026-1614 Rev 4 5-JAN-2013
CoreSense Device
Display (LCD)
No 3-Phase Power Trip
Contactor Coil Open 
Circuit
Current OverloadTrip
Phase Loss Trip
Welded Contactor
Warning
Low suction Pressure
Trip
Locked Rotor Trip
Motor Temp Trip Con-
trol Module
Protector Trip
High Discharge Pres-
sure Trip
Rack Controller Lock-
out
Part Winding Lockout
Low Oil Pressure Lock-
out
High Discharge Pres-
sure Lockout
Discharge Temp Lock-
out
Contactor Coil Lock-
out
Locked Rotor Lockout
Phase Loss Lockout
Control Module Fail-
ure Lockout
Normal Running
DLT xxx F
xxx-
AMPS
Inj Coil Open 
DLT xxx F
xxx-
AMPS
Inj Coil Short 
DLT xxx F
xxx-
AMPS
Fault Temp ProbeTrip
Inj Coil Open Fault
Temp Probe
Inj Coil Short Fault
Temp Probe
Compressor Low Volt-
age Lockout