Fujitsu ServerView Resource Orchestrator Cloud Edition V3.1.0 User Manual page 157

For infrastructure administrators (resource management) windows/linux
Hide thumbs Also See for ServerView Resource Orchestrator Cloud Edition V3.1.0:
Table of Contents

Advertisement

-
Port
Displays the port number for the external connection port. If the external port is a link aggregation group, the port numbers
of the member ports are displayed, separated by commas (",").
-
LAG
If the external port is a link aggregation group, the link aggregation group name is displayed.
-
Untagged VLAN
Displays the Untagged VLAN information set in the external connection port.
-
Tagged VLAN
Displays the Tagged VLAN information set in the external connection port, separated by commas (",").
Make the settings for the external port as follows.
a.
Click <Setting> in [VLAN ID/Uplink port settings] in the [Create a network resource] dialog.
The [Uplink port settings] dialog is displayed.
b.
Specify the uplink port to use when automatically setting external networks, including blade servers.
Select two ports to make into a pair.
For details on how to configure link aggregation on LAN switch blades, refer to "C.3.2 Preparations" in the "Design Guide
CE".
If there are multiple chassis
Select the all ports of the chassis to use.
When specifying a port in a link aggregation configuration (When specifying LAN switch blade PY CB Eth Switch/
IBP 10Gbps 18/8)
Set a link aggregation configuration on the uplink ports of LAN switch blades in advance, reflect the link aggregation
information for LAN switch blades, and then select a configured link aggregation group name.
When specifying a port in a link aggregation configuration (When specifying something else)
Confirm the settings of the LAN switch blade in advance, and select one or more ports for which link aggregation has
been configured.
The ports displayed for the selected targets of "Uplink ports" can be filtered based on the following items.
- "Filter ports by VLAN ID"
- Chassis name
- Switch name
- Location to mount
- Port number
- LAG name
If the VLAN auto-configuration of the external port is to be used, clear the [Filter ports by VLAN ID] checkbox, and
check the checkbox of the external port that was set up beforehand.
Do not specify for internal networks or external networks with rack mount servers only.
Subnet settings (Optional)
This setting can be omitted if [Public LAN] is specified for the type.
Enter if you want to automatically set a network and IP address for the NIC connected to the network resource when deploying
an image on an L-Server. IP addresses included in subnet addresses are allocated to L-Servers, but it is possible to specify a
range of addresses to exclude. Clicking <Add> will display the "Define start and end IP addresses" dialog, specify the range of
IP addresses to exclude, and click <Add>. To reactivate excluded IP addresses, check the appropriate checkboxes on the list,
and click <Delete>. Clicking <OK> displays the original dialog with the entered settings.
Network addresses and broadcast addresses are automatically excluded.
- 141 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serverview resource orchestrator cloud edition v3.1.1

Table of Contents