Table 1-26. LCD Status Messages
Code
Text
E1629 Power
required >
PSU wattage.
Check PSU and
config.
E1710 I/O channel
check error.
Review &

clear SEL.

E1714 Unknown
error. Review
& clear SEL.
E1810 Hard drive ##
fault. Review
& clear SEL.
E1812 Hard drive ##
removed.
Check drive.
E2010 Memory not
detected.
Inspect
DIMMs.
E2011 Memory
configuration
failure.
Check DIMMs.
(continued)
Cause
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
The system BIOS has
reported an I/O channel
check.
The system BIOS has
determined there has been
an error in the system, but
is unable to determine its
origin.
The SAS subsystem has
determined that the
specified hard drive has
experienced a fault.
The specified hard drive
has been removed from the
system.
No memory was detected in
the system.
Memory detected, but is
not configurable. Error
detected during memory
configuration.
Corrective Actions
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Check the SEL for details
of the error message.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
See "Troubleshooting
Hard Drives" on page 320.
Information only.
Install memory or reseat
the memory modules. See
"Troubleshooting Blade
Memory" on page 319.
See "Troubleshooting
Blade Memory" on
page 319.