Installing A Cmc Module - Dell PowerEdge M620 Owner's Manual

Hardware owner's manual
Hide thumbs Also See for PowerEdge M620:
Table of Contents

Advertisement

3 Reinstall the CMC module and reattach any cables that were
disconnected. See "Installing a CMC Module" on page 295.
On a single CMC system, the SD card activates automatically. For redundant
CMC module systems, initiate a changeover to make the passive module
active using the following steps:
1 Navigate to the Chassis page.
2 Click the Power Management tab.
3 Click the Control sub tab.
4 Select the Reset CMC (warm boot) button.
5 Click Apply.
The CMC automatically fails over to the redundant module, and that
module now becomes active and displays a solid blue status LED. The SD
card activates automatically.
See the CMC User's Guide for information on configuration and usage of the
FlexAddress feature.

Installing a CMC Module

1 Remove the I/O connector cover. See Figure 4-4.
2 Ensure that the CMC module handle is fully open.
3 Slide the module into the enclosure until the handle contacts the
enclosure.
4 To fully seat the module, close the handle until the release latch snaps into
place.
5 Reconnect the cables that were attached to the module.
Installing Enclosure Components
295

Advertisement

Table of Contents
loading